16
EN
•
Insert the auger (3) into the stainless steel filter (4) by pressing tightly until a click is
heard [Fig. H].
•
Insert the inlet (2) on the container (6) by aligning the open padlock ( ) with the
arrow on the container (▲) [Fig I] and rotate the inlet (2) clockwise to align the closed
padlock (
) with the arrow on the container (▲) [Fig L].
•
Placethe container for the juice (17) in front of the dispensing nozzle (8) and the
container for the waste (18) in front of the waste outlet (20).
USE
Proceed as follows after having assembled the appliance:
•
Insert the plug (15) in the socket.
•
The display (9) indicates speed 3.
•
Select the desired speed (1-2-3) by pressing the speed button (11).
•
Start the appliance by pressing the ON/OFF button (10).
•
Place the food inside the inlet (2).
•
If the food should stop in the inlet press it gently with the presser (1).
•
Once the juice is extracted, stop the appliance by pressing the ON/OFF button (10).
•
Disconnect the plug (15) from the socket.
•
Immediately clean the parts that have come into contact with food as described in the
CLEANING AND MAINTENANCE chapter.
CLEANING AND MAINTENANCE
After using the appliance, clean it immediately to prevent the food from clogging the
stainless steel filter (4) when it dries.
ATTENTION!
NEVER wash the removable parts in a dishwasher.
• Place the container for the juice (17) in front of the dispensing nozzle (8) and the
container for the waste (18) in front of the waste outlet (20).
•
Select the self-cleaning function by pressing the speed button (11) until the display
shows the symbol [ ] moving.
•
Start the appliance by pressing the ON/OFF button (10).
•
Pour water inside the inlet (2).
•
The self-cleaning function will last about 30 seconds after which the appliance will stop
automatically.
•
Disconnect the plug (15) from the socket.
•
Release the inlet (2) from the container (6) by rotating it anti-clockwise.
•
Remove the container (6) from the motor casing (14) by rotating it anti-clockwise.
•
Remove the filter (4) with the auger (3) inserted.
•
Tilt the filter (4) and remove the auger (3) and then the mixer drum (5) [Fig N].
•
Clean the dry dispensing nozzle under a jet of water by opening the silicone flap [Fig O].