PROBLEM
CAUSE
CORRECTIVE ACTION
The control panel does not switch on
- No electric power supply.
- Check the battery charge and the master
fuse.
- Circuit board fault.
- Stop pumping operations and contact the
authorised service centre
The starter motor does not run
- No power to the start motor.
- Check the battery charge, the master fuse
and start motor wiring.
The control panel switches on, but the
spark plug preheating indicator light
does not illuminate.
- Possible fault in the sparkplug preheating
relay.
- Check the operation of the relay and
replace it if necessary.
The starter motor runs but the diesel
engine does not start.
- Emergency button engaged.
- Reset the emergency button.
- Engine oil level too low.
- Top up the oil.
- No fuel.
- Fill the fuel tank and try again.
- Fuel is not being delivered to the engine
- Check the operation of the diesel solenoid
valve relay.
The battery light is on but the engine
does not start.
- The alternator is not charging.
- Check the alternator cable and replace it
if necessary.
The water temperature light is on but the
engine does not start.
- Insufficient coolant or radiator dirty.
- Add coolant, clean the radiator.
Pumping operations are interrupted.
- Unsuitable mixture
- Make the mixture more fluid.
- Safety grill open.
- Close the grill.
- Hydraulic fluid level too low.
- Top up the reservoir.
- Hydraulic fluid temperature too high.
- Check the fluid level and
clean the radiator; wait for the fluid to cool
down, with the engine running.
- One of the S valve or pumping piston
control solenoid valves is faulty.
- Check the solenoid valve wiring (see
wiring diagram) and check the led in
question lights up.
- Fault in one of the position sensors for the
S valve or the pumping pistons (check that
the led in question lights up).
- Check the position sensor wiring (see
wiring diagram).
The mixer does not work
- Distributor lever not raised.
- Raise the distributor lever
- Safety grill open.
- Close the grill.
- Foreign matter jamming the mixer. Check
the pressure on the pressure gauge.
- Remove the foreign matter / blockage in
the hose.
Pumping performance downgraded
- Wear plate or S valve disc worn.
- Adjust the S valve.
- Pumping pistons worn.
- Replace the pistons.
- Pumping mixture too dense.
- Make the mixture more fluid.
- S valve out of register
- Adjust the S valve.
Reduced pressure reading on the
pressure gauge (Fig. 19 Ref. 9) or
repeated S valve blockages
- S valve out of register
- Adjust the S valve.
Dirty water in the piston cooling tank.
- Pumping pistons worn.
- Replace the pistons.
The vibrating grill does not work
- Function deactivated at the control panel.
- Turn the switch (Fig. 14 Ref. 4) to the right
position.
- No electric power supply
- Check the wiring, the fit of the plug in its
socket and the operation of the relay.
The pressure water cleaner pump does
not work
- Distributor lever not raised
- Raise the distributor lever.
- No water delivery to the pump.
- Check that the intake hose is not crimped
or crushed. If necessary, place a water tank
at a suitable height and run the pump.
The set accelerant pump does not work
- Function not activated at the auxiliary
control panel.
- Activate the pump with the control panel
switch.
- Function activated in automatic, but with
pumping deactivated.
- Activate manual mode on the control
panel.
- Possible pump or hose blockage.
- Check for blockages in the hose and
remove them, taking the usual precautions
against contact with the skin and eyes.
- Electric board or control solenoid valve
fault.
- Check the wiring. If possible, stop
working, disconnect the solenoid valve
connector and manually adjust the
accelerant flow rate with the knob on the
solenoid valve.
Summary of Contents for 1106120
Page 16: ...16 IMER INTERNATIONAL S p A...
Page 17: ...17 IMER INTERNATIONAL S p A...
Page 30: ...30 IMER INTERNATIONAL S p A...
Page 31: ...31 IMER INTERNATIONAL S p A...
Page 44: ...44 IMER INTERNATIONAL S p A...
Page 45: ...45 IMER INTERNATIONAL S p A...
Page 58: ...58 IMER INTERNATIONAL S p A...
Page 59: ...59 IMER INTERNATIONAL S p A...
Page 72: ...72 IMER INTERNATIONAL S p A...
Page 73: ...73 IMER INTERNATIONAL S p A RICAMBI PI CES D TACH ES SPARE PARTS ERSATZTEILE REPUESTOS...
Page 75: ...75 IMER INTERNATIONAL S p A...
Page 83: ...83 IMER INTERNATIONAL S p A...
Page 89: ...89 IMER INTERNATIONAL S p A...
Page 93: ...93 IMER INTERNATIONAL S p A...