6. The front LED indicator will be slow flashing in red color during the upgrading process. When it
becomes steady on in green color, camera is ready to be accessed. Check the firmware version to
confirm that the system is successfully upgraded.
Recover device settings
In some cases, camera system does not respond to any operation. A certain recovering processes would help
to get the unit back to initial status, so that it can resume operable / configurable. This will be the operations
on the “Reset Button”.
1. Restart / Reboot the device
Short
Reset pin
and
Ground
pin
of the terminal block within 1 second; the system will be restarted.
2. Reset
User
Management
Short
Reset pin
and
Ground
pin
of the terminal block for 5~9 seconds; User management settings
will be reset to default and the system will be restarted.
3. Reset to factory default settings
Short
Reset pin
and
Ground
pin
of the terminal block for over 10 seconds; the system will be reset to
factory default and the system will be restarted.