13
4.4 Diag/Service
When online, follow the below operation to access Process Variables:
Online Menu→2 Diag/Service.
In Diag/Service Menu, there are three items: Test Device, Loop Test and Calibration.
Test Device
initiates a diagnostic routine at the device and can report an electronics
failure, as well as other failures that can affect performance.
Loop Test
can fix the transmitter output at a specified analogue value, and can be used to
test the integrity of the loop and the operation of devices in the loop.
Calibration
can include such operations as configuring output related parameters,
performing a sensor trim, or performing an analog output trim.
Figure 9 Diag/Service Menu
4.5 Basic Setup
When online, follow the below operation to access Basic Setup:
Online Menu→3 Basic Setup.
This menu provides quick access to a number of configurable parameters. The options
available here are the most fundamental tasks that can be simply performed with a given
device. These tasks are a subset of the options available under the Detailed Setup menu.
There are three interfaces of this menu: firstly, submenu, you can access to the
subordinate menu by pressing the Right Arrow Key; secondly, variable display, you can
read the read-only variables or change the readable variables here; thirdly, special
functions, you can do a series of operation here to achieve a specific function.
Figure 10 Basic Setup
4.6 Detailed Setup
When online, follow the below operation to access Detailed Setup:
Online Menu→4 Detailed Setup.
Online
(
*******
)
Diag/Service
1 Test Device
2 Loop test
3 Calibration
Online
(
*******
)
Basic setup
1 Distributor
2 Model
3 Dev id
4 Tag
5 Device information
6 Revision