H375A HART
Hand Held Communicator
Manual
INTNERNATIONAL METAL ENGINEERING PTE LTD
Page 1: ...1 H375A HART Hand Held Communicator Manual INTNERNATIONAL METAL ENGINEERING PTE LTD...
Page 2: ...ce lifetime of the LCD display will be shortened if the device is insolated in the sun NOTE 3 If the device will not be used for a long period of time please make sure that the batteries be removed fr...
Page 3: ...ion 8 2 2 HART Connector 8 2 3 PC Connector 8 2 4 Power Supply 8 2 5 Battery Use 8 2 6 Temperature Requirements 8 2 7 Liquid Crystal Display LCD 8 Section 3 Keypad Instruction 3 1 On Off Key 10 3 2 Up...
Page 4: ...ation With Field Device 17 5 2 Communicator Power up Failure 17 5 3 Special Function Application Failure 17 Appendix Appendix 1 8080HT Menu Tree 18 Appendix 2 ROSEMOUNT 1151 Menu Tree 19 Appendix 3 RO...
Page 5: ...achieve the configuration of instrument parameters upper limit and lower limit etc the reading of instrument variables as well as the diagnosis and maintenance of the instrument This Communicator cou...
Page 6: ...tor once again for shut down Then for about 5 seconds after the startup the Communicator will automatically poll the HART device polling address 0 in the 4 20mA loop If a device is not found the Commu...
Page 7: ...rim is usually done when the HART instruments leave factory or when the periodic inspection of the instrument Only authorized person could be designated to do this work or any inappropriate operation...
Page 8: ...ormation on software update 2 4 Power Supply Power Supply 4 5V DC Electricity Consumption 91 3mA Standard value under working state 1uA Standard value under sleep state 2 5 Battery Use Power Supply Th...
Page 9: ...mperature is too low the response time of the LCD will be longer It is normal phenomenon When the ambient temperature is too high as embedded the automatic temperature compensation circuit the LCD wil...
Page 10: ...focused option 3 7 Alphanumeric and Shift Keys Use Alphanumeric Keys to input data Figure 5 Figure 5 Alphanumeric and Shift Keys 3 8 Using Shift Keys for Data Entry Some menu requires data entry Use...
Page 11: ...example to enter the letter R press the following key sequence Press the right Shift Key to activate the shift function press the 6 key an R appears in the editable field Press the Shift Key again to...
Page 12: ...y capacity 3 Polling You can access the Main Menu by pressing the previous menu key several times Figure 6 Main Menu 4 2 Online Menu If the Communicator is connected to a HART instrument you can acces...
Page 13: ...operation to access Basic Setup Online Menu 3 Basic Setup This menu provides quick access to a number of configurable parameters The options available here are the most fundamental tasks that can be s...
Page 14: ...ator If the DD is not presented in the HART Communicator please do not hesitate to contact with us The Online Menu can be different depending on the connected device Please refer to the device specifi...
Page 15: ...ress1 to address 15 1 Online 2 Battery 3 Polling 1 Process variables 2 Diag Service 3 Basic setup 4 Detailed setup 1 Test Device 2 Loop test 3 Calibration 1 Apply value 2 D A trim 3 Sensor trim 1 Dist...
Page 16: ...ery at once to avoid influence on the normal use of the Communicator 4 7 3 Polling Follow the below operation to access Battery Capacity Main Menu 4 Polling When several devices are connected in the s...
Page 17: ...has been installed with battery Check if the battery installation of the Communicator is correct Check if the battery capacity has been used up 5 3 Special Function Application Failure You have comple...
Page 18: ...word 4 Sensor information 1 PV Snsr s r 2 PV Snsr Unit 3 PV LSL 4 PV USL 5 PV Min span 1 PV Unit 2 PV URV 3 PV LRV 4 PV Damp 5 Xfer fnctn 6 AO Alrm type 1 Wrt protect menu 2 Loca Adiust 1 Format 2 AO...
Page 19: ...vice info 4 Sensor infomation 1 PV Snsr s r 2 PV Snsr Unit 3 PV LSL 4 PV USL 5 PV Min span 1 PV Unit 2 PV URV 3 PV LRV 4 PV Damp 5 Xfer fnctn 6 AO Alrm type 1 Zero trim 2 Upper sensor trim 3 Lower sen...
Page 20: ...V Min span 1 PV Unit 2 PV URV 3 PV LRV 4 PV Damp 5 Xfer fnctn 6 AO Alrm type 7 Alarm Sat Levels 1 Num req preams 2 Universal rev 3 Fld dev rev 4 Software rev 5 Hardware rev 1 Meter type 2 CM Setup 1 f...
Page 21: ...condition 1 PV Snsr s r 2 PV Snsr Unit 3 PV LSL 4 PV USL 5 PV Min span 1 PV Unit 2 PV URV 3 PV LRV 4 PV Damp 5 Xfer fnctn 6 AO Alrm type 7 Low cut 8 Cut mode 9 Bi dir mode 10 H2O Unit select 11 SI Opt...
Page 22: ...condition 4 Field device info 5 Sensor information 6 transmitter info 1 PV Snsr s r 2 PV Snsr Unit 3 PV LSL 4 PV USL 5 PV Min span 1 PV Unit 2 PV URV 3 PV LRV 4 PV Damp 5 Xfer fnctn 6 AO Alrm type 1...
Page 23: ...V Snsr s r 2 PV Snsr Unit 3 PV LSL 4 PV USL 5 PV Min span 1 PV Unit 2 PV URV 3 PV LRV 4 PV Damp 5 Xfer fnctn 6 AO Alrm type 7 Cut Pt 8 Cut Mode 1 zero trim 2 upper sensor trim 3 lower sensor trim 4 Sn...
Page 24: ...nsor information 5 LCD Display mode 1 PV Snsr s r 2 PV Snsr Unit 3 PV LSL 4 PV USL 5 PV Min span 1 PV Unit 2 PV URV 3 PV LRV 4 PV Damp 5 Xfer fnctn 6 AO Alrm type 1 Snsr Zero Cal 2 Snsr Span Cal 3 Res...