background image

E2W1-2000-PL Rev 11-01-11    PG- 3

IMC SOLAR EAGLE

®

5/8TH SCALE INTERNAL DRAWING WITH METAL 

COVER AND H-V WIRING ACCESS COVER REMOVED 

PL REV DATE

HIGH LIMIT DIAL-ADJ.
KNOB STYLE VARIES

POWER WIRING PER
LOCAL CODES-
USE 16,18 GA. SOLID;
12,14 GA. STRANDED.
1 OR 2 OF SAME GA.
UNDER EACH CLAMP

CIRCUIT POWER (2.4W)

:

EG- EARTH GROUND  
N-    NEUTRAL (WHT)
L -   120VAC  10% (BLK)

±

120 VAC 20 AMP 
RELAY JUMPER

MOUNT ENCLOSURE WITH 2 #10 SCREWS SPACED 5.25 IN.

1/2” CONDUIT 4-HOLES
2 BOTTOM & 1 EA. SIDE

RELAY (PUMP/FAN):

(UL & CSA LISTED)

WITH 120V JUMPER

NO- 20 A RES; 1 HP
NC- 15 A RES; 1/4 HP

WITHOUT JUMPER

COM- 240 VAC 
NO- 20 A RES; 2 HP
NC- 15 A RES; 1/2 HP

DIFFERENTIAL
DIAL-ADJ.
KNOB STYLE VARIES

USE 1/8” WIDE BLADE 
SCREW DRIVER. 
TURN CCW TO OPEN
HOLE FOR WIRE 
(22 TO 18 GA)

TEMP. SENSORS (4)

:

COL-  COLLECTOR 
POL-  POOL
AX1 & 2- OPTIONAL

NEC CLASS 2 CIRCUITS

SHLD WIRE- 
CONNECT TO SENSOR
CABLE SHIELDS

OVERRIDE JUMPERS: (ONE OR NONE)
FZ- FREEZE PROTECT (40 ON 55 OFF)
LO- LOW LIMIT COL (50 OFF 70 ON)

RELAY (PUMP) 
OVERRIDE SWITCH
AUT- NORMAL SETTING

DATA PORT FOR
IMC ACCESSORIES
ONLY - SEE MANUAL!

DATA REFRESH
JUMPER: 2 SEC / 6 MIN

REV: 09-25-11

PR# E2W1-2000-PL

NOTICE:
The DATA PORT’s “RJ-45” is NOT an ethernet or network connection!

“BOLT-ON” sensors

SENSORS 

are Industrial grade 10K IMC thermistors rated for 

400°F with +/-1°F accuracy.  When installed properly, they will 
not exceed ONE degree of additional error for cable distances 
up to 1000 ft. of 18 ga., 700 ft. of 20 ga. or 500 ft. of 22 ga.  
Two “BOLT-ON” sensors are included with each controller 
(except -WA & -SP).  See “Accessories” section for available 
probe types and sizes.

OVERRIDE JUMPERS: (ONE OR NONE)
FZ- FREEZE PROTECT (37 ON 52 OFF)
LO- LOW LIMIT COL (50 OFF 70 ON)

RELAY (PUMP) 
OVERRIDE SWITCH
AUT- NORMAL SETTING

DATA REFRESH
JUMPER: 2 SEC / 6 MIN

PR# E2W1-2000-PLIP

ISOLATED DATA
PORT: FOR IMC
ACCESSORIES
ONLY- SEE MANUAL!

SPECIFICATIONS

 

Controller Power Input:

2.5 Watts Minimum @ 120VAC  10% 50/60HZ

 

Power Relay Contact Ratings:

Common (CM)-

30VDC MAX. or 240VAC MAX. 

Normally Open (NO)- 

20A Resistive @ 120VAC & 240VAC
1 HP @ 120VAC; 2 HP @ 240VAC 
20A @ 30VDC; TV-5

Normally Closed (NC)- 

15A Resistive @ 120VAC & 240VAC
1/4 HP @ 120VAC; 1/2 HP @ 240VAC 
15A @ 30VDC

 

Relay Action:

30sec delay ON; no delay OFF

Differential:

Adjustable 4 to 16 F; fixed 4 F reset

High Limit:

Adjustable 70 to 105 F; fixed 4 F reset

Accuracy:

+/- 1  F

Sensors:

10K @ 77 F (25 C) Rated to 400 F

Environmental:

-10 to 120 F @ 0 to 95 %RH

Dimensions & Weight:

5.00”W x 6.12”H x 2.50”D;  Appx. 2.5 lbs

±

°

°

°

°

°

°

°

°

°