  9 

MAINTENANCE 

To prolong the service life and to ensure the maximum 

performance of the searchlight, we recommend the following 
maintenance guidelines : 

Dirt on front glass and/or mirror reflector will result in a 

considerable loss of light.  Before every voyage the equipment 
should be checked on these points as well as on good working of 
the lamp. 

 
Periodical maintenance is recommended at least once every three months. 
 
Before opening the searchlight for cleaning and/or inspection of the interior the supply 
must be disconnected. 
 
Procedure : 
Remove front glass and bezel assembly 
 
Inspect the lampholder, ensure that it is free from dirt and corrosion. 
Inspect the lamp. The quartz envelope must be bright and clear. 
Replace if necessary. 
 
Check all seals and rubber mountings of the mirror reflector. 
Replace if necessary. 
 
Check earthing point for conductivity 
 
Check small ventholes in the bottom to be open  
 
Check lamp supply cable on wear and tear. 
 
After the inspection : Clean frontglass inside and outside, and clean the mirror reflector 
with a proprietary glass cleaner. Cleaning the mirror reflector  does not harm the 
silvering because the silver layer is on the back of the glass. 
 
Finally : Test searchlight for full working for 20 odd minutes. 

 
 
 
 
 

Summary of Contents for IM400RCX

Page 1: ......

Page 2: ......

Page 3: ......

Page 4: ...s 3 Technical Information 4 Pre Installation Instructions 5 Electrical Installation 6 Diagrams and Assembly drawings 7 Operating Instructions 8 Fault Finding 9 Maintenance and Servicing 10 Spare Parts...

Page 5: ...highest engineering standards The design of the product is based on many years of experience in the field of Marine Lighting it is made to withstand the environmental conditions in both offshore and...

Page 6: ...and wear goggles to ensure a safe working environment Searchlights get very hot Never touch the unit when lit Always allow it to cool down for 15 to 20 minutes after it has been switched off Never pla...

Page 7: ...at resistant front glass Optical data for the IM490RC 1000W T H 2000W T H Supply voltage 115 230V 115 230V Peak Beam Candle Power 2 098 000 cd 2 748 300 cd Range 1 448 mtr 1 657 mtr Divergence 5o 8o 5...

Page 8: ...d dry environment In case the unit has been in storage for several months it is advised to conduct a routine maintenance check before it is installed in its definite position SAFETY Do not connect the...

Page 9: ...l that full operating voltage is applied to the lampholder in order to obtain maximum performance of the lightsource Method of Electrical Connection Disconnect the supply before working on the electri...

Page 10: ...IM08095 Wiring diagram single panel control IM08096 Wiring diagram single panel control optional focus control IM08097 Wiring diagram multi panel control with Electronic Interlocking IM400 111 Outlin...

Page 11: ...re that the searchlight is isolated from the supply before changing the lamp The envelope of a lamp is made in glass or quartz which materials are inherently fragile please bear this in mind when hand...

Page 12: ...archlight motor housing from the bottom Check input 230 V and 24Vac output on the transformer Measure 24Vac input on terminals 1 2 on motor controller junction J3 If 24Vac on the input is present outp...

Page 13: ...disconnected Procedure Remove front glass and bezel assembly Inspect the lampholder ensure that it is free from dirt and corrosion Inspect the lamp The quartz envelope must be bright and clear Replace...

Page 14: ...10 10 SPARE PARTS LISTS...

Page 15: ......

Page 16: ......

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ......

Page 21: ......

Page 22: ......

Reviews: