Warning and error information
B6 incorporates a variety of functions for the systems to verify processes and the state of the
electronics. In case of an error the screen will display the cause of error and emit an audible
sound.
R E V E R S E P O L AR I T Y
C O N N E C T I O N B R E AK
S H O R T E R R
I N P U T V O L ER R
V O L S EL E C T ER R
B R E A K D O W N
Incorrect polarity connected.
Battery connection is interrupted.
Short-circuit of the output termination.
Erroneous selection of voltage of Lithium pack, please check the voltage
of the battery pack.
The voltage of the battery pack has been selected incorrectly!
The charger has malfunctioned for some reason. Seek professional
advice.
B A T T E R Y CH E C K
L O W VO L T A G E
The voltage is lower than which is set. Please check the number of cells
in the battery pack.