Charging of the Pb battery
Charging of the Pb battery
Battery
type
DEC
P b C H A R G E
4 . 0 A 1 2. 0 V ( 6 P )
P b - 6 4 . 0 A 12 . 5 9 V
C H G 0 2 2 : 43 0 0 6 8 2
-
Batt type
Stop
Elapsed
time
INC
+
Charge
current
Battery
voltage
DEC
Start
Enter
-
‘>3 seconds’
INC
+
Charged
capacity
Set up the charge current on the left and nominal voltage on the right.
Range of current is 0.1-5.0A, the voltage should match the battery being
charged. Press START/ENTER key for more than 3 seconds to start
charging.
T h e s c r e e n d i s p l a y s t h e r e a l - t i m e d i s c h a r g i n g s t a t u s . P r e s s
START/ENTER key to alter discharge current. Press START/ENTER key
again to store the parameter value you set. Press BATT TYPE/STOP key
to end the program.
Discharging of t he Pb batteryy
DEC
P b D I S C HA R G E
1 . 0 A 12 . 0 V ( 6 P )
-
Batt type
Stop
INC
+
DEC
Start
Enter
-
‘>3 seconds’
INC
+
Set up the charge current on the left and nominal voltage on the right.
Range of discharge current is 0.1-5.0A, the voltage should match the
battery being charged. Press START/ENTER key for more than 3
seconds to start charging.
P b - 6 0 . 4A 1 2 . 5 9 V
D S C 0 2 2 :4 3 0 0 6 8 2
T h e s c r e e n d i s p l a y s t h e r e a l - t i m e d i s c h a r g i n g s t a t u s . P r e s s
START/ENTER key to alter discharge current. Press START/ENTER key
again to store the parameter value you set. Press BATT TYPE/STOP key
to end the program.
Battery
type
Elapsed
time Discharge
current
Battery
voltageDischarged
capacity
24