![Imagine Selenio SEL-1DEC1 Installation And Operation Manual Download Page 15](http://html1.mh-extra.com/html/imagine/selenio-sel-1dec1/selenio-sel-1dec1_installation-and-operation-manual_2045397015.webp)
SELENIO™ SEL‐1DEC1/SEL‐1DEC2
Installation and Operation Manual
Installing Selenio Modules in an MCP3 Frame
© 2014 Imagine Communications Corp. Proprietary and Confidential.
Version 7.0 | Page 15
Installing Selenio Modules in an
MCP3 Frame
Where space allows, Selenio DEC1 and DEC2 modules can be installed in any MCP3 frame. Additionally,
Selenio DEC2 modules are available as part of pre‐configured MCP1 packages.
You can insert a Selenio module into an MCP3 frame with the power supply turned on or off. Follow this
procedure:
1.
Remove a blank back module from the frame, saving the blank back modules and their captive
screws for future configurations.
2.
Attach the new back module to the empty slot, using the mounting screws provided.
Align the back module’s pin into the guide hole, and ensure that the EMI gaskets separating the back
modules remain in place during the installation. The EMI gaskets fit tightly. To ease the installation
of back modules, gradually press each back module into place from the left side to the right side.
Figure 5:
Installing Back Modules
3.
Apply labels to the back module, if these are supplied separately.