Front Fan Module
The 1 and 2 RU Platinum VX frames have four fans that are connected directly to the main board.
The 4 RU Platinum VX frame has 2 fan modules, with 4 fans mounted on each fan.
The 8 RU Platinum VX frame has 16 fans mounted on four front fan modules.
Since the 4 and 8 RU Platinum VX frames both have redundant Crosspoint/Control modules, grouping
the fans on separate fan modules ensures the active Crosspoint/Control Module is cooled if the
redundant Crosspoint/Control Module is removed in order to be serviced.
When the frame is powered up, by default, the fans initially run at full speed, and then stabilize to
normal speed in a minute or so.
If any of the fans in the group fail, an alarm is triggered (see Fault Descriptions (see "System Fault
Descriptions" on page 137)).
CAUTION: Front Fan modules are the main source of cooling for the entire system. In the event of a fan
failure, ensure that you replace the fan as soon as possible to prevent overheating.
Fan Status
Each fan reports its status to the control system. Fan Status is presented to users in different ways:
Frame
SOFTWARE STATUS
HARDWARE STATUS
Alarm
Chassis Fan Status
Fan LEDs
1 RU
An Alarm
is triggered
if a fan fails.
See Fan Alarms (on
page 40)
Color status indicators
on the
Control System dashboard
indicate fan status.
See Chassis Fan Status on the
Controller Dashboard (on page
37)
No fan specific LEDs, see
System LEDs (on page 79)
2 RU
3 RU
Fan LEDs
on the outside of the
frame indicate fan status.
See Fan Status on LEDs on the
Frame (see "Fan Status
Hardware LEDs on the Frame"
on page 38)
4 RU
Chassis Fan Status on the Controller Dashboard
The main dashboard has fan status graphically represented with red (alarm or missing) and green (good)
software LEDs as fan status indicators.
1 and 2 RU frames have indicators for each of the 4 fans on board.