Platinum™ VX
Installation and Operation Manual
Alarms and LEDs
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
Version 1.2 | Page 79
Alarms and LEDs
System LEDs
3 LEDs on the frame indicate Crosspoint Control and System Status. If the Alarm LED is on, it indicates a
system level problem such as a fan failure.
Figure 54:
System LEDs on 1/2 RU Frames
Figure 55:
System LEDs on 4/8 RU frames
Table 29:
System LEDs
LED
Applicable
Frames
Color
Description
Alarm Level
ON / Active LED
4/8 RU
Green Crosspoint is powered
Informational
Amber Active Crosspoint
Informational
Sync LED
All
Solid
ON
Sync reference is present.
Informational
Alarm LED
All
Red
This LED is enabled:
When the Resource Module
(PVX-RES) is in failsafe mode
(solid red)
During LLDC identification
(flashing red)
Informational
Power
1/2 RU
Green Frame is powered
Informational