Platinum™ VX
Installation and Operation Manual
Module Configuration
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
Version 1.2 | Page 132
Terminate
: Terminates current transition with a ‘Cut’
Undo
: Undoes the current transition, reverting to the previous state
For more details, see CQS 1/2 A/B (Advanced) (on page 116).
Reference Menu
Set the following options in the
Reference
menu:
Reference Select
Specify the reference signal to use for switch operation.
External Ref
: External reference provided to frame will be used for CQS
Free-run
: Internal reference will be used. (mainly for testing purposes)
If Free-run is selected, the reference standard (
Standard for Free Run
parameter) must be
specified and set to 23.98Hz, 24Hz, 30/60Hz, 29/59Hz, or 25/50Hz. Note that this parameter is
hidden if an External reference is selected.
Video Sync Mode
Set to Frame Sync or Line Sync.
Note: The Reference Standard parameter displays the reference signal detected by the CQS module.
For more details, see Reference Parameters (on page 114).
Advanced Settings Menu
This menu contains processing parameters for each input channel. For each CQ switch, there are two
inputs, A and B.
Set options as required. For example:
Frame Sync Output Standard
Select the video standard for both
Program
and
Preview
output. If
Follow Input Standard
(default) is selected and there is an LOV at the input, the output standard remains unchanged.
V-Phase and H-Phase
Adjust the vertical and horizontal phase of the frame sync
Transition Rate (ms)
Select the duration of the transition. The default is 0 msec, which automatically sets the
transition type to ‘Cut’.
LOV Mode
Select the output signal when LOV is detected at the input
Freeze Mode
Select the frozen video type (Field 1, Field 2. Frame). This parameter is only visible when LOV
Mode is set to Freeze.
For more details, see Advanced Setting (on page 115) parameters.