37
4
Connector Pinouts
This chapter provides information on NXAMP3801HDX/HDI pinouts, jumper settings, Weidmüller GPI input
and output circuits and connect wiring.
COM PORT Pinouts
RJ-12 to DB-9
Table 4-1
shows the RJ-12 to DB-9 pinout descriptions for NXAMP3801HDX/HDI.
Table 4-1
RJ-12 to DB-9 Adapter
RJ-12 Connector
RJ-12
Connector
pins
Function
DB-9 Connector
Pin Location
DB-9 Master DB-9 Slave
1
RC+
7
3
2
RC-
2
8
3
TX-
8
2
4
TX+
3
7
5
Shield
9
9
6
Not Used
1
1
Weidmüller GPI Connectors
Specifications
NXAMP3801HDX/HDI has two 16-pin Weidmüller female connectors on the back panel (refer to
Figure 2-6
on page 24), one for the GPI
IN
(
Figure 4-1
on page 38)and one for the GPI
OUT (
Figure 4-2
on page 39).