881A/L-GS Scanning Sonar
Doc No: 430-044-00
Page
32
of
46
Suspend sonar operations, and mount the sonar on a level stable surface, or settle the ROV on a flat
bottom.
Select Options > Calibrate Gyro.
The message Calibrating Gyro will appear. Calibration takes approximately 30 seconds.
Once the message disappears, standard operation commences.
Note
: When using manual biasing, it is ESSENTIAL that the sonar remains completely stationary and at constant
temperature during gyro calibration. Any movement will cause undesirable drift in the gyro.
3.5.6.
Options > Enable Gyro Auto Bias
Realtime only.
Puts the sonar into auto bias mode where the sonar will continuously re-bias the gyro in real time. Disabling this
mode requires periodic manual calibration. See Section 3.5.5 Options > Calibrate Gyro.