The hydrotherapy spa is designed to seat seven
adults. The spa holds approximately 300 gallons of
water and offers a heating system (80°F to 104°F), a
filtration system, and adjustable hydrotherapy jets.
Follow the guidelines below to use and maintain the
spa for your long-term enjoyment.

WIRING THE HYDROTHERAPY SPA

The hydrotherapy spa is designed to operate with a
240-volt power source. It must be wired directly into a
grounded circuit with a Ground Fault Circuit
Interrupter (GFCI) capable of carrying 40 amps. No
other appliance should be on the same circuit.

Connection of the spa to the 240-volt power
source must be performed by a qualified, licensed
electrician and must comply with all local, state,
and federal electrical codes.

Please refer to the

instructions on the inside of the electronics package
for information about connecting the spa to a 240-volt
power source.

Once the spa is filled with water, the power can be
turned on. Note: The first time the power is turned on,
the spa will start automatically.

TESTING AND TREATING THE WATER

The first time you use the spa, you should test and
treat the water. 

You must also treat the water each

time you refill the spa. 

A test strip and a chemical

pack are available at your local pool and spa supplier.
Follow the directions carefully on the chemical pack to
test and treat the water. 

Always keep the chemicals

away from children and pets.

See WATER CHEM-

ISTRY on page 13 for information concerning proper
water maintenance.

STARTING THE HYDROTHERAPY SPA

You should always test the GFCI before using the
hydrotherapy spa. First, turn on the spa by pressing
the pump button on the console (see USING THE
CONTROLS on page 12). Once the spa is running,
press the GFCI “test” button. The spa should shut off.
Press the “reset” button. The spa should resume nor-
mal operation. If the spa continues to run after the
“test” button is pressed, the GFCI is damaged. Do not
use the spa until the GFCI has been repaired or
replaced by a qualified electrician.

Once you have tested the GFCI, you should verify the
water flow from the pumping unit. Set the air controls
to the lowest setting (see USING THE CONTROLS
on page 12). The pumping unit will heat the water as
it pumps. Cover the hydrotherapy spa with the spa
cover. 

The spa cover must be tight

(see SECUR-

ING THE SPA COVER ON THE SPA on this page).
The water will heat at about 6°F per hour with the
cover on. If you are using the spa indoors, and the
room temperature is maintained at 70°F, it will take
approximately 6 to 8 hours for the water to reach the
set temperature.

The temperature and the water flow can be set or
changed with the controls on the console (see USING
THE CONTROLS on page 12).

SECURING THE SPA COVER ON THE SPA

To secure the spa cover,
snap the latches on the spa
cover into the buckles on the
premium cedar panels.

To lock the buckles, insert
the key and turn it clock-
wise 1/4 turn. To unlock the
buckles, insert the key and
turn it counterclockwise 1/4
turn. 

Always keep the

buckles locked when the
spa is not in use. Keep the keys in a safe place,
out of the reach of children.

Using the Hydrotherapy Spa

Latch

Key

Buckle

Summary of Contents for IMSW73910

Page 1: ...ne will provide immediate assistance free of charge CUSTOMER HOT LINE 1 877 897 7493 Mon Fri 6 a m 6 p m MST Model No IMSW73910 Serial No The serial number is on a sign behind the access panel Write the serial number in the space above CAUTION Read all precautions and instruc tions in this manual before using this equipment Save this manual for future reference Visit our website at www workoutware...

Page 2: ...16 Part List 18 Exploded Drawing 19 Ordering Replacement Parts Back Cover Limited Warranty Back Cover The warning sign shown below must be posted on a wall or fence where it will be visible to all users of the hydrotherapy spa Whenever the spa is moved the sign must also be moved and reposted near the spa If the sign becomes lost or illegible call our toll free Customer Hot Line at 1 877 897 7493 ...

Page 3: ...es can cause significant damage such as blistering of the shell surface and warping of the spa shell Any damage caused by sun exposure is not covered under the warranty 9 Do not bring any object into the hydrotherapy spa that could damage the spa shell 10 Never insert any object into any opening 11 Do not use breakable containers in or near the hydrotherapy spa 12 Do not sit on the spa cover or pl...

Page 4: ...injury Pregnant women should consult with their physician before using the hydrotherapy spa Pregnant women should not use the spa if the water temperature is above 100 F the unborn child could be seriously harmed This is especially important during the first 90 days of the pregnancy 29 DANGER To reduce the risk of drowning Prolonged immersion in the hydrotherapy spa may cause hyperthermia The caus...

Page 5: ...RNING The spa jets produce a stream of water with relatively high pressure Prolonged exposure of a localized area of the body may cause bruises to the skin 36 The included warning sign must be posted where all users of the hydrotherapy spa can see and read it See POSTING THE WARNING SIGN on page 2 37 WARNING DECAL PLACEMENT Locate the decals shown below and familiarize yourself with the informatio...

Page 6: ... best For your benefit read this manual carefully before using the IMAGE RENEW 739 If you have ques tions after reading the manual please call our Customer Service Department toll free at 1 877 897 7493 Monday through Friday 6 a m until 6 p m Mountain Time excluding holidays To help us assist you please mention the product model number and serial number when calling The model number is IMSW73910 T...

Page 7: ...f the spa provided you leave access to the motor for service 9 Be sure to note any other considerations such as aesthetics or privacy concerns that may affect the safety or enjoyment of using the spa If you set up the hydrotherapy spa outside 1 Check local building codes concerning the use of outdoor spas 2 The spa should be located near a 240 volt power source It must be wired directly into a gro...

Page 8: ...ngs Read each assembly step before you begin Tighten all parts as you assemble them unless instructed to do otherwise ASSEMBLY REQUIRES THE FOLLOWING TOOLS not included One phillips screwdriver A wire connector is provided on the electronics pack of the spa to connect a minimum No 6 AWG 13 3 mm2 solid copper conductor between the spa and any metal equipment electrical enclosure made of metal metal...

Page 9: ...ositions 4 The hydrotherapy spa operates on a 240 volt power source and must be wired directly to a 40 amp Ground Fault Circuit Interrupter GFCI installed in your home This procedure must be performed by a qualified licensed electrician A wiring diagram is found on the inside of the electronics package for reference Under no circumstances should the spa be wired by someone other than a qualified e...

Page 10: ...er water maintenance STARTING THE HYDROTHERAPY SPA You should always test the GFCI before using the hydrotherapy spa First turn on the spa by pressing the pump button on the console see USING THE CONTROLS on page 12 Once the spa is running press the GFCI test button The spa should shut off Press the reset button The spa should resume nor mal operation If the spa continues to run after the test but...

Page 11: ...chemical treatment H The console controls the spa jets turns the under water light on and off and adjusts the water tem perature setting see USING THE CONTROLS on page 12 I The four air controls regulate the air flow to the whirlpool hydrotherapy and volcano jets J The two neck jets can be adjusted to spray sooth ing water on your neck To activate the neck jets turn the on off valve P counterclock...

Page 12: ... filters the water when the spa is left unattended When the power to the spa is first turned on or if the water temperature is below the set temperature the water will be heated as required Note To keep the filter and heat cycles from running the power to the spa must be turned off Light Button Turns the underwater light on and off Temperature Buttons Control the temperature setting of the water T...

Page 13: ...asive cleaner on the entire cover Rinse the cover with a garden hose to remove any cleaner residue Dry the cover entirely Use a non silicone based vinyl conditioner on the cover after you clean it This will help protect the cover from sun damage CHECKING AND CLEANING THE FILTERS The filters should be checked periodically for build up of dirt and oil If the filters need to be cleaned follow the ste...

Page 14: ... to sanitize the spa CHANGING THE FILTER CYCLE The spa will filter the water every 12 hours The dura tion of the cycle can be adjusted to last 2 to 5 hours Press the temperature up or temperature down button on the console When the display begins to flash press the pump 1 button The display will read F2 To change the time press the temp up button until the desired time is reached Press the pump 1 ...

Page 15: ... the spa see DRAINING THE HYDROTHER APY SPA on the previous page and this page 3 Remove all remaining water from the spa shell Dry the spa shell with towels 4 Set the air controls to the lowest setting Use a wet dry vacuum to pull any remaining water from the system To do this place the vacuum nozzle over each jet starting with the highest jet and fin ishing with the lowest jet 5 Set the air contr...

Page 16: ... F per hour If you are using the spa indoors and the room temperature is main tained at 70 F it will take approximately 6 to 8 hours for the water to reach the set temperature b If you are using the hydrotherapy spa outdoors it may take longer for the water to heat See the chart below for the approximate heating time Air Temperature Heating Time 70 F 6 to 8 hours 50 F to 70 F 9 to 11 hours 30 F to...

Page 17: ...ace the damaged seal b Some water loss due to evaporation is normal If rapid water loss occurs or if you notice wet ness on the floor around the hydrotherapy spa the spa shell may have a leak Contact your local pool and spa service provider for repairs 10 SYMPTOM THE SPA JET UNIT CONTINUES TO RUN AFTER IT HAS BEEN SHUT OFF a To turn the main jets off press pump button 1 once or twice Note If the a...

Page 18: ...nsole 30 1 Hose Washer 31 8 1 4 Washer 32 1 Diverter Valve 33 1 Trim Plate 34 1 Foam Weir 35 1 Volcano Jet 36 3 Nozzle Housing 37 21 Small Rotator 38 1 Large Rotary Jet 39 1 Face Ring 40 1 Small Nozzle 41 22 Jet Ring 42 1 Nozzle Bushing 43 21 Pivot Ring 44 3 Medium Nozzle 45 2 Drain Plug 46 32 10 x 2 Sheet Metal Screw 47 1 Pillow 48 2 Drain Plug O ring 49 1 On Off Valve Handle 50 1 Hose Cap 51 1 S...

Page 19: ...8 11 13 10 9 31 13 13 19 9 31 13 20 1 12 2 15 37 43 44 36 40 39 41 42 41 38 35 46 46 16 17 16 17 16 17 16 17 46 46 25 6 6 9 5 3 4 5 3 4 47 45 48 45 48 49 14 9 9 54 52 53 53 23 23 Exploded Drawing Model No IMSW73910 R0901A ...

Page 20: ... following incidents any damage to the premium cedar surround or frame attributable to improper handling or freight damage damage resulting from improper winterization damage to the spa shell resulting from improper chemical treatment damage to the spa shell resulting from exposure to extreme temperatures or damage to the spa shell resulting from expo sure to direct sunlight and ultraviolet rays w...

Reviews: