To drain the hydrotherapy spa, follow the steps below:

1. Using the console, adjust the temperature to the

lowest setting.

2. Shut off the power at the circuit breaker or GFCI.
3. Remove the long access panel from the spa.
4. Remove the end of the drain hose from the spa.

Remove the cap and attach a garden hose to the
drain hose.

5. Open the valve by turning the valve knob. The

water will begin to drain.

6. When the spa is empty, close the valve and

remove the garden hose. Re-attach the cap and
return the drain hose to the clip inside the spa. 

7. Re-attach the access panel.
8. Refill the spa and treat the water with chemicals

(see pages 10 and 14).

DRAINING THE PUMP

After the hydrotherapy
spa is drained (see
DRAINING THE
HYDROTHERAPY SPA
on page 14), the jet
pump should also be
drained if the spa will
be stored for more than
thirty days or if it may
be exposed to freezing
temperatures.

Turn off the spa power. To drain the jet pump, first
remove the access panel from the spa unit (see
ATTACHING AND REMOVING ACCESS PANELS on
page 14). Locate the jet pump inside the spa. Remove
the drain plug from the jet pump and allow all of the
water to drain. Re-attach the drain plug.

WINTER USE AND CARE

The hydrotherapy spa is designed for year-round use.
If you decide to store the spa for the winter, store it in
a warm, dry location. Follow the steps below to winter-
ize the spa.

1. Drain the spa (see DRAINING THE HYDROTHER-

APY SPA on the previous page and this page).

2. Remove all remaining water from the spa shell. Dry

the spa shell with towels.

3. Set the air control to the lowest setting. Use a

wet/dry vacuum to pull any remaining water from
the system. To do this, place the vacuum nozzle
over each jet, starting with the highest jet and fin-
ishing with the lowest jet. 

4. Set the air control on the console to the highest

setting and repeat step 3.

5. Drain the pump (see DRAINING THE PUMP on

this page). Once the water is drained from the
pump, place the vacuum nozzle over the drainage
hole in the pump and vacuum any additional water
from the pump. Note: For additional protection,
remove the pump/motor from the spa and store
it in a climate-controlled room.

6. Clean the spa shell (see page 13).
7. Clean the filter (see page 13).
8. A licensed, qualified electrician should discon-

nect the power from the 240V power source.

9. Re-attach the access panel and the spa cover.

REPLACING THE LIGHT BULB

If the underwater light burns out, you will need to
remove the access panel to replace it (see ATTACHING
AND REMOVING ACCESS PANELS on page 14).
Make sure that the power to the spa is turned off.
Next, locate the light housing. Turn the light housing
counterclockwise and remove it from the spa shell.

To replace the light bulb, pull the old light bulb out of
the housing and insert a new light bulb. Re-attach the
light housing to the spa shell. Re-attach the access
panel to the spa.

Drain Plug

Drain

Hose

Valve

Knob

Cap

Light Housing

Light

Housing

Light

Bulb

Summary of Contents for IMSB61610, IMSG61610

Page 1: ...immediate assistance CUSTOMER HOT LINE 1 877 897 7493 Mon Fri 6 a m 6 p m MST CAUTION Read all precautions and instruc tions in this manual before using this equipment Save this manual for future ref...

Page 2: ...6 Part List 18 Exploded Drawing 19 Ordering Replacement Parts Back Cover Limited Warranty Back Cover The warning sign shown below must be posted on a wall or fence where it will be visible to all user...

Page 3: ...s can cause significant damage such as blistering of the shell surface and warping of the spa shell Any damage caused by sun exposure is not covered under the warranty 9 Do not bring any object into t...

Page 4: ...injury Pregnant women should consult with their physician before using the hydrotherapy spa Pregnant women should not use the spa if the water temperature is above 100 F the unborn child could be seri...

Page 5: ...ll users of the hydrotherapy spa can see and read it See POSTING THE WARNING SIGN on page 2 37 WARNING DECAL PLACEMENT Locate the decals shown below and familiarize yourself with the information on th...

Page 6: ...t you need to feel your best For your benefit read this manual carefully before using the RENEW 616 If you have questions after reading the manual call our Customer Service Department toll free at 1 8...

Page 7: ...spa provided that you leave access to the motor for service 9 Be sure to note any other considerations such as aesthetics or privacy concerns that may affect the safety or enjoyment of using the spa I...

Page 8: ...of metal metal water pipes or conduit within five feet of the spa 1 Before beginning assembly make sure that you have read and understand the information in the box above and on the previous two page...

Page 9: ...ectronics package as a reference Under no circumstances should the spa be wired by someone other than a qualified electrician Before you have the spa wired make sure that it is in the desired position...

Page 10: ...proper water maintenance STARTING THE HYDROTHERAPY SPA You should always test the GFCI before using the hydrotherapy spa First turn on the spa by pressing the jet button on the console see USING THE...

Page 11: ...ble directional jets can be pivoted to direct the water flow G An optional ozone generator can be purchased and installed to utilize the ozone jet Ozone provides a way to help sanitize the spa with mi...

Page 12: ...drotherapy If the button is pressed twice the spa jets will run at high speed providing moderate pres sure hydrotherapy If the button is pressed again the jets will shut off The spa also features an a...

Page 13: ...p solution do not use solvents The spa should always be clean and dry before being moved or stored MAINTAINING THE SPA COVER The spa cover should be cleaned monthly To clean the spa cover use water an...

Page 14: ...testing and adjusting the pH CHANGING THE FILTER CYCLE The spa will filter the water every 12 hours The dura tion of the cycle can be adjusted to last 2 5 hours Press the temp up or temp down button o...

Page 15: ...1 Drain the spa see DRAINING THE HYDROTHER APY SPA on the previous page and this page 2 Remove all remaining water from the spa shell Dry the spa shell with towels 3 Set the air control to the lowest...

Page 16: ...main tained at 70 F it will take approximately 6 to 8 hours for the water to reach the set tempera ture b If you are using the hydrotherapy spa outdoors it may take longer for the water to heat See th...

Page 17: ...MPTOM NO AIR FLOWS THROUGH THE ADJUSTABLE HYDROTHERAPY JETS WHEN THE AIR CONTROL IS TURNED COUNTER CLOCKWISE a If no air flows through the hydrotherapy jets when the air control is turned counterclock...

Page 18: ...ber Washer 30 4 Buckle 31 8 4 x 3 4 Screw 32 4 Flared Nozzle 33 1 Filter Cover O ring 34 2 Air Control Knob 35 1 Cover Ring 36 3 Nozzle Housing 37 4 Nozzle Retainer Ring 38 4 1 4 Washer 39 1 Rotator 4...

Page 19: ...6 26 30 31 21 27 28 13 20 11 2 7 25 26 10 18 17 13 9 38 38 38 38 29 29 29 4 6 19 23 36 39 35 32 37 12 3 19 22 18 19 24 51 5 1 8 16 33 14 9 9 52 52 19 53 54 Exploded Drawing Model No IMSB61600 IMSG6160...

Page 20: ...llowing incidents any damage to the cedar surround or steel frame attributable to improper handling or freight damage damage resulting from improper winterization damage to the spa shell resulting fro...

Reviews: