background image

Refer to the diagram above. The function of each
component is explained below. 

A. The four adjustable, directional jets can be pivot-

ed to direct their water flow. To open the jets, turn
the rims counterclockwise; to close the jets, turn
the rims clockwise. If no air flows through the jets,
turn the jets counterclockwise. Close the jets to
increase the water pressure to other jets. 

B. The adjustable, pulsing jet produces a soothing,

pulsing massage action. To open the jet, turn the
rim counterclockwise; to close the jet, turn the rim
clockwise.

C. The large rotary jet features two jets of water that

provide a pulsing, spinning massage action. Turn
the jet counterclockwise to open it or clockwise to
close it.

D. The four whirly jets provide a continuous whirling

massage action.

E. The three medium adjustable, directional jets

can be pivoted to direct the water flow. Turn the
rims of the jets to open and close them.

F. The two small adjustable, directional jets can be

pivoted to direct the water flow.

G. An optional ozone generator can be purchased and

installed to utilize the ozone jet. Ozone provides a
way to help sanitize the spa with minimal chemical
treatment.    

H. The skimmer cleans the surface of the water.

I. The temperature probe monitors water temperature.

J. The underwater light can be used for night opera-

tion (see USING THE CONTROLS on page 12).

K. The two suction vents near the floor of the spa

bring water into the pumps in order to operate the
system. Never operate the spa without the suc-
tion covers in place. 

L, M. The air controls determine the amount of air

flowing through the indicated jets during opera-
tion (see USING THE CONTROLS on page 12).

N. The filter can be removed for cleaning or replace-

ment (see CHECKING AND CLEANING THE FIL-
TER on page 13). 

O. The console controls the jets, turns the underwater

light on and off, and adjusts the water temperature
setting (see USING THE CONTROLS on page 12).

P. The three pillows can be removed or turned 180°

to provide two positions of comfort.

11

Spa Shell Diagram

K

K

E

G

J

N

D

A

E

A

P

P

P

A

F

A

D

O

L

M

C

B

H

I

Summary of Contents for IMSB61610, IMSG61610

Page 1: ...immediate assistance CUSTOMER HOT LINE 1 877 897 7493 Mon Fri 6 a m 6 p m MST CAUTION Read all precautions and instruc tions in this manual before using this equipment Save this manual for future ref...

Page 2: ...6 Part List 18 Exploded Drawing 19 Ordering Replacement Parts Back Cover Limited Warranty Back Cover The warning sign shown below must be posted on a wall or fence where it will be visible to all user...

Page 3: ...s can cause significant damage such as blistering of the shell surface and warping of the spa shell Any damage caused by sun exposure is not covered under the warranty 9 Do not bring any object into t...

Page 4: ...injury Pregnant women should consult with their physician before using the hydrotherapy spa Pregnant women should not use the spa if the water temperature is above 100 F the unborn child could be seri...

Page 5: ...ll users of the hydrotherapy spa can see and read it See POSTING THE WARNING SIGN on page 2 37 WARNING DECAL PLACEMENT Locate the decals shown below and familiarize yourself with the information on th...

Page 6: ...t you need to feel your best For your benefit read this manual carefully before using the RENEW 616 If you have questions after reading the manual call our Customer Service Department toll free at 1 8...

Page 7: ...spa provided that you leave access to the motor for service 9 Be sure to note any other considerations such as aesthetics or privacy concerns that may affect the safety or enjoyment of using the spa I...

Page 8: ...of metal metal water pipes or conduit within five feet of the spa 1 Before beginning assembly make sure that you have read and understand the information in the box above and on the previous two page...

Page 9: ...ectronics package as a reference Under no circumstances should the spa be wired by someone other than a qualified electrician Before you have the spa wired make sure that it is in the desired position...

Page 10: ...proper water maintenance STARTING THE HYDROTHERAPY SPA You should always test the GFCI before using the hydrotherapy spa First turn on the spa by pressing the jet button on the console see USING THE...

Page 11: ...ble directional jets can be pivoted to direct the water flow G An optional ozone generator can be purchased and installed to utilize the ozone jet Ozone provides a way to help sanitize the spa with mi...

Page 12: ...drotherapy If the button is pressed twice the spa jets will run at high speed providing moderate pres sure hydrotherapy If the button is pressed again the jets will shut off The spa also features an a...

Page 13: ...p solution do not use solvents The spa should always be clean and dry before being moved or stored MAINTAINING THE SPA COVER The spa cover should be cleaned monthly To clean the spa cover use water an...

Page 14: ...testing and adjusting the pH CHANGING THE FILTER CYCLE The spa will filter the water every 12 hours The dura tion of the cycle can be adjusted to last 2 5 hours Press the temp up or temp down button o...

Page 15: ...1 Drain the spa see DRAINING THE HYDROTHER APY SPA on the previous page and this page 2 Remove all remaining water from the spa shell Dry the spa shell with towels 3 Set the air control to the lowest...

Page 16: ...main tained at 70 F it will take approximately 6 to 8 hours for the water to reach the set tempera ture b If you are using the hydrotherapy spa outdoors it may take longer for the water to heat See th...

Page 17: ...MPTOM NO AIR FLOWS THROUGH THE ADJUSTABLE HYDROTHERAPY JETS WHEN THE AIR CONTROL IS TURNED COUNTER CLOCKWISE a If no air flows through the hydrotherapy jets when the air control is turned counterclock...

Page 18: ...ber Washer 30 4 Buckle 31 8 4 x 3 4 Screw 32 4 Flared Nozzle 33 1 Filter Cover O ring 34 2 Air Control Knob 35 1 Cover Ring 36 3 Nozzle Housing 37 4 Nozzle Retainer Ring 38 4 1 4 Washer 39 1 Rotator 4...

Page 19: ...6 26 30 31 21 27 28 13 20 11 2 7 25 26 10 18 17 13 9 38 38 38 38 29 29 29 4 6 19 23 36 39 35 32 37 12 3 19 22 18 19 24 51 5 1 8 16 33 14 9 9 52 52 19 53 54 Exploded Drawing Model No IMSB61600 IMSG6160...

Page 20: ...llowing incidents any damage to the cedar surround or steel frame attributable to improper handling or freight damage damage resulting from improper winterization damage to the spa shell resulting fro...