1  INTRODUCTION 

With  the  iQ-FoV-Box,  you  have  a  chart  illumination  and  positioning  system  optimized  for  resolution 

measurements of high FoV cameras up to 180 degrees. Together with the iQ-Analyzer, it is a complete 

automatic detection and analysis solution for two different chart setups. In the following manual, you will 

find a detailed description of how to use this system to get the best measurement performance.  

If you assemble your iQ-FoV-Box by yourself, please follow the separate installation manual.  

Safety note: If the power supply gets interrupted or there is a power failure, the illumination may 

execute a reset and start again with 1 % brightness. 

 

2  STARTING THE SYSTEM 

2.1  Placement 

Place your iQ-FoV-Box in a dry condition and on even ground. Ensure that there is enough space around 

the box. You need full access to the back door and enough space to adjust the alignment arm on the 

front side to the full length.  

2.2  Starting/Control overview 

Connect the box to power and turn it on with the power switch placed on the control panel at the lower 

left edge of the front wall of the box. On the right side of the control panel are the illuminance intensity 

knob,  the  illumination on/off  button,  and  a  USB port.  This  USB  port directly  connects  to  the  camera 

mounting inside the box. You do not need to put a control or power cable inside the box.  

The box is now ready for starting with camera and chart alignment. The alignment tools and chart setups 

will be described in the following chapters.  

 

3  CAMERA AND CHART ALIGNMENT 

You  can  choose between  two different  chart  setups  when  using  your  iQ-FoV Box.  These setups  will 

allow  you  to  analyze  your  images  automatically  with  the  iQ-Analyzer-X.  For  high  performance,  it  is 

crucial to  align  your  camera  inside the box and position the three  different  chart types  in  the  correct 

areas. 

 

Summary of Contents for iQ-FoV Box

Page 1: ...Image Engineering GmbH Co KG Im Gleisdreieck 5 50169 Kerpen Germany T 49 2273 99 99 1 0 F 49 2273 99 99 1 10 www image engineering com iQ FoV Box User Manual August 8 2022 ...

Page 2: ... SYSTEM 3 2 1 Placement 3 2 2 Starting Control overview 3 3 CAMERA AND CHART ALIGNMENT 3 3 1 Camera depth and height 4 3 2 Camera pitch and yaw 4 3 3 Camera fine leveling 4 3 4 Chart positioning 5 4 ILLUMINATION INTENSITY 6 5 CHART HANDLING 6 6 FIELD OF VIEW CALCULATION 7 ...

Page 3: ...ox You need full access to the back door and enough space to adjust the alignment arm on the front side to the full length 2 2 Starting Control overview Connect the box to power and turn it on with the power switch placed on the control panel at the lower left edge of the front wall of the box On the right side of the control panel are the illuminance intensity knob the illumination on off button ...

Page 4: ...ide the box and the camera s optical axis is centered For camera depth and height alignment use the mechanical positioning of the extension arm from the outside of the box Depending on your camera s FoV and dimensions you may have to adjust the depth height or leveling again when adjusting the chart positions as described in the following chapters We suggest starting with chart setup 1 to align th...

Page 5: ...e chart C in the center of the back wall The other charts must be positioned on a straight vertical and horizontal line through the image center The vertical placement has to have one chart A on the top using the top wall and one chart B at the bottom using the bottom floor wall The horizontal placement has to be done similarly place one chart B on the left wall and one chart A on the right wall U...

Page 6: ...l knob outside the device The intensity panel shows the actual intensity in percent Turn on off the tubes via the on off button To get the best performance measure adjust the intensity so that the brightest area of the OECF grey patch fields around the center chart C is on its possible maximum but not saturated You can put the density filters over the fluorescent tubes for low intensity use The ac...

Page 7: ...distances a1 2 b1 2 and d in the following formula to calculate the angle of view for horizontal angle for vertical angle d is the distance the camera moved into the iQ FoV Box measured from the front plate see the left side of Image 04 The measure s origin is shown in Image 04 on the right side and is located in the center of the front plate Please note that it is essential to center the camera f...

Reviews: