iQ-FoV Box 

 

 

 

User Manual 

 

 

August 8, 2022 

 

Summary of Contents for iQ-FoV Box

Page 1: ...Image Engineering GmbH Co KG Im Gleisdreieck 5 50169 Kerpen Germany T 49 2273 99 99 1 0 F 49 2273 99 99 1 10 www image engineering com iQ FoV Box User Manual August 8 2022 ...

Page 2: ... SYSTEM 3 2 1 Placement 3 2 2 Starting Control overview 3 3 CAMERA AND CHART ALIGNMENT 3 3 1 Camera depth and height 4 3 2 Camera pitch and yaw 4 3 3 Camera fine leveling 4 3 4 Chart positioning 5 4 ILLUMINATION INTENSITY 6 5 CHART HANDLING 6 6 FIELD OF VIEW CALCULATION 7 ...

Page 3: ...ox You need full access to the back door and enough space to adjust the alignment arm on the front side to the full length 2 2 Starting Control overview Connect the box to power and turn it on with the power switch placed on the control panel at the lower left edge of the front wall of the box On the right side of the control panel are the illuminance intensity knob the illumination on off button ...

Page 4: ...ide the box and the camera s optical axis is centered For camera depth and height alignment use the mechanical positioning of the extension arm from the outside of the box Depending on your camera s FoV and dimensions you may have to adjust the depth height or leveling again when adjusting the chart positions as described in the following chapters We suggest starting with chart setup 1 to align th...

Page 5: ...e chart C in the center of the back wall The other charts must be positioned on a straight vertical and horizontal line through the image center The vertical placement has to have one chart A on the top using the top wall and one chart B at the bottom using the bottom floor wall The horizontal placement has to be done similarly place one chart B on the left wall and one chart A on the right wall U...

Page 6: ...l knob outside the device The intensity panel shows the actual intensity in percent Turn on off the tubes via the on off button To get the best performance measure adjust the intensity so that the brightest area of the OECF grey patch fields around the center chart C is on its possible maximum but not saturated You can put the density filters over the fluorescent tubes for low intensity use The ac...

Page 7: ...distances a1 2 b1 2 and d in the following formula to calculate the angle of view for horizontal angle for vertical angle d is the distance the camera moved into the iQ FoV Box measured from the front plate see the left side of Image 04 The measure s origin is shown in Image 04 on the right side and is located in the center of the front plate Please note that it is essential to center the camera f...