background image

 

System Restore 

 

 

31 

System Restore 

Solid State Disk Software Error 

The file system and Linux operating system of a Scan2Net scanner are very 
robust and fault tolerant. The file system is capable of repairing itself even 
if the system loses power during a hard drive write, which would almost 
certainly damage any Windows, Android, or MAC operating system based 
computer. However, it is still possible for the Scan2Net Linux software on 
the SSD to become corrupted under certain circumstances. Unexpected 
power outages, hard shutdowns via the main power switch without a prior 
controlled shutdown, and other unexpected interruptions to the operating 
system can cause this type of disruption. In addition, any uncontrolled 
interruption of a firmware update procedure or other functions that 
involve writing to main storage (SSD) poses a potential risk to the integrity 
of the firmware on the SSD. The Scan2Net operating system of any 
WideTEK® or Bookeye® scanner is Linux based and although it is very rare, 
Linux can be corrupted like any other operating system. 
 
If the Linux operating system or other parts of the SSD are damaged, there 
is still no need to replace the SSD, at least not until the recovery procedure 
is performed once. These recovery procedures are similar to the 
procedures necessary to restore other operating systems to a previous 
state. 

  

Recovery points 

Up to two backup copies of the Scan2Net Linux operating system are 
stored on the internal SSD. The first copy is created during manufacturing. 
This is the restore point labeled "Factory Default". The second can be 
created by the user at any time. This is the restore point labeled "User 
Settings". 

  

Summary of Contents for WideTEK 24F

Page 1: ...WideTEK 24F Setup Instructions English 06 2021...

Page 2: ...port 7 Contact details of the manufacturer in the USA 7 Device safety 8 Intended use 8 Basic safety instructions 9 Responsibility of the operator 10 Personnel qualification 10 Design features of warni...

Page 3: ...n scanner 22 Switch off scanner 24 Perform setup 26 Setup Wizard 26 Perform calibrations 28 Activate setup menu 28 System Restore 31 Solid State Disk Software Error 31 Recovery points 31 System Restor...

Page 4: ...o safely prepare and perform the setup for the WideTEK 24F flatbed scanner The WideTEK 24F flatbed scanner is hereinafter referred to as the scanner The start button is referred to as the power button...

Page 5: ...s guide have specified design features This allows you to easily distinguish the following elements normal text BUTTONS OF THE SCREEN menu labels Action steps first level enumeration Cross references...

Page 6: ...n features in illustrations When elements are referred to in a legend or in the running text they are given a number 1 Associated documents Accompanying documents include Legal information EC declarat...

Page 7: ...red trademarks of Image Access all other trademarks belong to their respective owners Contact details of the manufacturer in Germany Image Access GmbH Hatzfelderstra e 161 163 42281 Wuppertal Tel 49 2...

Page 8: ...nding this manual and observing and following all instructions in this manual especially the safety instructions Any other use is expressly considered improper and will void any warranty and liability...

Page 9: ...t Image Access technical support see the Technical Support section beginning on page 7 Avoid burns Do not cover the existing openings in the scanner housing They are used for ventilation Otherwise the...

Page 10: ...containing abrasive additives solvents or acids Use a damp microfiber cloth Only operate the touchscreen with your finger or a suitable conductive pen with a rubber tip Other objects can damage the to...

Page 11: ...death or serious injury CAUTION Notes with the word CAUTION warn of a situation that may result in minor or moderate injury The following symbols are used in the warnings Symbol Explanation Danger due...

Page 12: ...as size weight must comply with the specifications found in the technical data The scanner is intended for use in closed rooms in the commercial sector Intended use also includes observing and followi...

Page 13: ...Description 13 Overview WideTEK 24F No Designation 1 Removable and height adjustable lid 2 Glass plate 3 Touchscreen 4 Reset button 5 Power button 6 USB connection socket...

Page 14: ...canner No Designation 1 Main power switch 2 Connection socket 24 V DC for external power adapter 3 Network connection socket 4 DisplayPort connector socket 5 USB connection socket 6 Connection socket...

Page 15: ...ay of the menu designation 3 Display of online help 1 4 Button for exiting the setup menu to the start screen 5 Display of the serial number 6 Display of the IP address 7 Display of the firmware versi...

Page 16: ...is located on the back of the scanner The following figure shows the rating plate of the WideTEK 24F model Serial number The serial number of the scanner is located on the back of the device Keep the...

Page 17: ...perated in five ways Via the touch screen and the ScanWizard Touch user interface Via EasyScan or a client application Via a standard web browser and the ScanWizard Client interface Via the optional S...

Page 18: ...r on a level and stable base The load bearing capacity of the base must be suitable for the weight of the scanner maximum 50 kg 110 lbs The dimensions of the base must be suitable for the footprint of...

Page 19: ...bruises and crushing Lay the connection cables so that no one can trip over them To connect the power supply proceed as follows Make sure the scanner s main power switch is turned off 0 position Use o...

Page 20: ...low Connect one plug of the supplied network cable to the network connection jack on the back of the scanner Connect the second plug to the network connection socket of an existing network Connecting...

Page 21: ...o the DisplayPort connector on the back of the scanner Connecting the optional touch screen CAUTION Incorrect routing of the connection cables can cause tripping broken bones bruises and crushing Lay...

Page 22: ...are setup 22 Switch on scanner To switch on the scanner proceed as follows Press the MAIN POWER SWITCH 1 to the I position The following figure shows the WideTEK 24F model The scanner is in stand by m...

Page 23: ...23 To exit stand by mode proceed as follows Press the power button 2 The power button lights up blue The scanner performs a system test After a short waiting time the Startup Screen screen is display...

Page 24: ...e Select Application screen tap SHUTDOWN 1 You can also press the POWER button briefly to access this menu Do not press the POWER button for longer than 5 seconds otherwise the scanner will be forced...

Page 25: ...ded period of time you can further reduce power consumption by turning off the stand by power To do this follow the steps below Make sure the scanner is in stand by mode Press the MAIN POWER SWITCH 1...

Page 26: ...after the startup process is complete The Setup Wizard allows the user to perform the most important settings on the touch screen during the initial installation of a Scan2Net scanner After the Setup...

Page 27: ...scanner can be reactivated in the DEVICE SETUP section of Scan2net Open a tab in a web browser and enter the IP address assigned to the scanner in the address bar The Scan2Net window will appear Click...

Page 28: ...Perform calibrations 28 Perform calibrations Activate setup menu To activate the setup menu you must log in To do this proceed as follows Tap on the GEAR SYMBOL 1...

Page 29: ...n data in the login window To do so tap the corresponding input field with your finger The on screen keyboard is displayed Enter Poweruser in both input fields Note that the input is case sensitive To...

Page 30: ...ess Display the IP Address submenu Wireless Network Display the WLAN submenu User Settings Display the User Settings submenu Time and Date Display the Time and Date submenu Touchscreen Test Display th...

Page 31: ...n of a firmware update procedure or other functions that involve writing to main storage SSD poses a potential risk to the integrity of the firmware on the SSD The Scan2Net operating system of any Wid...

Page 32: ...cess is not interrupted by a hard shutdown or power failure If this process is interrupted loss of the system restore point is possible so the SSD must be physically replaced The following process can...

Page 33: ...d the READY message is displayed The entire process takes about 1 2 minutes System Restore Step Action 1 Open a tab in a web browser and enter the IP address of the scanner 2 The Scan2Net window appea...

Page 34: ...ropping problems occur even though the document is in the correct area of the scan area To avoid electric shock and other potential damage make sure the scanner is turned off and unplugged before clea...

Page 35: ...9 3 9 3 m Sensortype CIS line sensor with long focal length selfoc lens depth of field 1mm 600dpi Color Depth 48 bit color internal resolution 16 bit grayscale internal resolution Scan Modes 24 bit c...

Page 36: ...e Humidity 20 to 80 non condensing ECO Standard CEC Level VI Scanner Voltage 24 V DC Current Max 5 A Illumination System Light Source RGB LEDs with integrated diffusor tested according to IEC 62471 no...

Page 37: ...00 mm 5 5 x 29 x 36 inch Weight Scanner 28 kg 62 lbs Dimension Transport Box H W D 250 x 800 x 1000 mm 10 x 31 5 x 40 inch Scanner Weight Ready to Ship 33 kg 73 lbs Ambient Conditions Operating Temper...

Page 38: ......

Reviews: