Imada MV-500NII Series Instruction Manual Download Page 3

Instruction Manual MX-500N / MV-500NII Series 

 
 

Manual No. 

MXV50801E

 

INTRODUCTION 

    Thank  you  very  much  for  adopting  Imada  product.  MX/MV-500N  series  is  the  force 

measuring  instrument  which  combines  with  Imada  brand  digital  force  gauge  or 

mechanical  force  gauge.    It  measures  tensile  and  compressive  force  by  motorized 

stable speed.    Moreover, in case large force is measured, there is no fatigue. Optional 

length/speed meter meets the demands for investigation of connection between length 

and force. 

    In order enough to utilize this machine, be sure to read this instruction manual before 

use.    Please  keep  it  carefully  after  reading.    Although  produced  and  shipped  at  the 

origin  of  a  severe  quality  control  of  our  company,  and  inspection,  if  there  is  a  doubtful 

point, if possible, please inform to your local dealer or us. 

 

 

Cautions of the overload of a force gauge; 

 

No  matter  if  its  power  supply  is  ON  or  OFF,  it  will  be  damaged  when  the  force 

exceeding tolerance level is applied.   

 

Force  gauge  will  be  damaged  if  its  sensing  shaft  is  applied  a  bending  or  torsion 

force. 

 

Force gauge will be damaged by the force beyond its capacity. 

 

Please follow the instruction manuals of attachment for each product about use of a 

force gauge. 

 

Cautions of storage. 

 

Please avoid oil, dust, and heat and high humidity, and keep it in a cool place.   

 

After use, please protect the measuring shaft of a force gauge form load or a shock. 

 

Please do not use organic solvents, such as thinner, for removing the dirt.

 

Summary of Contents for MV-500NII Series

Page 1: ...ST STAND MX 500N Series MV 500NII Series Before use read through this instruction manual to use this unit correctly Keep this instruction manual as this includes a Certificate of warranty Uploaded by...

Page 2: ...Instruction Manual MX 500N MV 500NII Series 2 Manual No MXV50801E...

Page 3: ...produced and shipped at the origin of a severe quality control of our company and inspection if there is a doubtful point if possible please inform to your local dealer or us Cautions of the overload...

Page 4: ...nvert the force gauge and test stand Cautions on safe Please use it after protecting an eye the body and this unit when danger boiling water and a fragment and a dangerous chemistry substance scatter...

Page 5: ...V 500NII Series 5 Manual No MXV50801E OVERVIEW Limit knobs Table Crosshead Grip mount GF 1 Operation panel Force gauge mount H mm Model H T MX MV 500N S 573 285 MX MV 500N S L 773 485 MX MV 500N E 633...

Page 6: ...auge mount Rear view EN 00 connector is only for MX 500N E or MV 500NII E series 4 holes 4 5 mm dia For digital force gauge 4 holes 3 5 mm dia For mechanical force gauge IO Connector MV Series EN 00 C...

Page 7: ...s 7 Manual No MXV50801E Operation panel MX series MV series Emergency button Power switch Speed volume Mode LED Run LED FS LED Up Down buttons Mode button FS button Run LED Up Down Buttons Emergency b...

Page 8: ...ct certain force gauge here to use Force control mode through an optional cable CB 501 EN 00 Connector MX MV E series only Connect a speed Length meter EN 00 here Operation panel Page 7 Emergency butt...

Page 9: ...und Supplies Below supplies are included with this unit GF 1 grip mount 1 Power supply cord 1 Fuse 1 This instruction manual 1 Carton box 1 Allen key for M3 1 Allen key for M4 1 Allen key for M8 1 M3...

Page 10: ...V 500NII E Scale unit MX 500N S MV 500NII S Long stroke MX 500N L MV 500NII L Long stroke Speed Length meter MX 500N E L MV 500NII E L Long Stroke Scale unit MX 500N S L MV 500NII S L Attach the follo...

Page 11: ...Functions Manual Single cycle Continuous cycle Force control 1 Overload stop 1 Manual Crosshead runs up and down with motor Adjustable upper lower travel Adjustable speed Recommended force gauge IMAD...

Page 12: ...orce gauge to mount with remaining M6 flat head screws in the hole 3 Insert the tip of M6 flat head screws into the holes on the crosshead Tighten it by flap nuts Especially the force gauge of low cap...

Page 13: ...500N S A scale unit included with MX MV 500N S series can display travel length of the crosshead so that you can measure elastic character and so on For details see an instruction manual for the scal...

Page 14: ...peration After plugging EN 00 turn on the test stand to display length and speed Press zero button when the crosshead is at the original position Speed is always displayed Please refer the instruction...

Page 15: ...use any tool to tighten an attachment to the sensing shaft of the force gauge to prevent it from overload Adjusting upper and lower limit 1 Press to select Manual Operation 2 Press to drive crosshead...

Page 16: ...starts by It will reverse its travel direction when it reaches travel limit at its maximum speed It automatically stops at another travel limit Continuous cycle mode Continuously goes up and down betw...

Page 17: ...e It stops when you release the button or when it gets to each limit knob Operation in Single cycle mode 1 Select Single cycle mode by button 2 Whenever pressing toggles FS Effective LED lights up and...

Page 18: ...rosshead running to the direction of button figure at its maximum speed The crosshead reverses when it gets to the limit knob at its maximum speed Until pressing some Up Down button or Mode button it...

Page 19: ...d Decrease speed when a signal of comparator is OK Stops when a signal is NG Automatically keeps the force for the comparator signal to be OK Force gauges corresponding with above features as of 2006...

Page 20: ...e at its maximum speed It does not start if the comparator signal from the gauge does not indicate NG The crosshead increase speed to be indicated by the speed knob or the FS volume when the comparato...

Page 21: ...u release button Light Blink Keep Pressing or for 2 seconds Crosshead continues moving although you release button Light Blink Press or while running Crosshead stops Blink Dark Crosshead stops always...

Page 22: ...anship and material under normal use and proper maintenance for one year from original purchase During the warranty period we will at our option either repair or replace defective products Please cont...

Page 23: ...Instruction Manual MX 500N MV 500NII Series 23 Manual No MXV50801E...

Page 24: ...mption items such as batteries or attachments Negligence or accident such as fire earthquake or flooding Deficiencies of this document Failures caused by consumption articles 3 Ask your local dealer o...

Reviews: