others. These are classified by degree of danger, damage and seriousness. All indicators concern 
safety and should be followed. 
 

Classification 

Degree of Danger or Damage and Seriousness 

 

DANGER 

Explains an instruction where death or serious injury may occur. 
 

WARNING 

Explains an instruction where bodily injury or damage to device may occur. 
 

CAUTION 

Explains an instruction where possibility for minor to medium bodily injury or 
damage to device may exist. 
 

 

DANGER 

 

Do not install, use this product or fill it with maintenance oil in room with a risk of explosion or    
flames. 

 

Do not install or use the product in direct sunlight or where the temperature exceeds 40C (104F) 

 

Do not use the product for other purposes than the maintenance (cleaning and lubrication) of 
handpieces described in this operation manual. 

 

Provide adequate ventilation. In the unlikely event of odours seek immediate ventilation.

 

 

WARNING 

 

Do not handle the power cord with wet hands. 

 

Be careful not to spill water onto the unit. May result in fire, electric shock or short-circuit.   

 

Do not disassemble or alter the unit. In case of service or repair, contact your dealer. 

 

In unlikely event of burning or smoke, immediately turn off the power switch and disconnect the 
power plug. Contact your dealer. 

 

Do not drop the unit. Place the unit on a flat surface. 

 

Only use fuses with rating, 120v: T800mAl250V, 220v/240v: T400mAl250V

 

 

 

Summary of Contents for HCR-100

Page 1: ...1 iM3 HCR 100 Automatic Handpiece Cleaning Lubrication System OPERATION MANUAL...

Page 2: ...UTIONS 3 1 FEATURES 5 2 SPECIFICATIONS 6 3 PARTS NAME 7 4 INSTALLATION AND ASSEMBLY 7 5 OPERATION PROCEDURES 8 6 DOOR 11 7 MAINTENANCE 11 8 TROUBLE SHOOTIING 12 SAFETY PRECAUTIONS Read these safety ca...

Page 3: ...use the product in direct sunlight or where the temperature exceeds 40C 104F Do not use the product for other purposes than the maintenance cleaning and lubrication of handpieces described in this op...

Page 4: ...sure above 0 35Mpa Do not open the oil cap during operation Open only after the unit completely stops When opening the oil cap in case of abnormal stop opening the door wait for approx 5 seconds befor...

Page 5: ...r effectively and efficiently cleans and lubricates contra angle handpiece Pressing the air key can purge excess oil from the handpiece after lubrication and cleaning cycle to some extent Select the l...

Page 6: ...6 2 SPECIFICATIONS Model SC L1 Rated Voltage AC120V10 AC230V10 50 60Hz Input Voltage 24 0VA Air Pressure 0 25 0 3Mpa 2 5 3 0kgf cm2 50 85psi Dimensions W280 D275 H360mm Weight 6 8kg...

Page 7: ...ll it to the full level while checking the oil level gauge After filling oil screw the oil cap back on tight DANGER Do not fill maintenance oil in the room with a risk of an explosion or near open fla...

Page 8: ...lose the door securely Contra Angle Handpiece 1 Remove the bur from the handpiece 2 Open the door of the unit and attach the handpiece to the E type joint until it locks 3 Point the bur insertion hole...

Page 9: ...cation cycle 5 When the cleaning and lubrication cycle is completed the mode indicator turns on and the buzzer sounds to tell the completion of the cycle 6 Pressing the air key blows out air only from...

Page 10: ...ng the air key 2 In 1 2 seconds or less press the start key The mode indicator changes at that time S L lighting The buzzer sounds L E lighting The buzzer does not sound 3 After selecting either press...

Page 11: ...leaning cycle 4 or 5 times before use to secure stable oil absorption of mist filters Alternatively apply maintenance oil directly to mist filters before use CAUTION Replace oil absorbent sheets appro...

Page 12: ...burned The unit does not clean and lubricate Does the mode indicator light Is the door open Remove the air tube press all three selection buttons and press start button Does the Unit produce an operat...

Reviews: