Im-en Export Frijters Rijsbergen B.V LaserOP 3.0 Instruction Manual Download Page 4

2 LASEROP

2.1 

INTENDED USE IN PROFESSIONAL ENVIRONMENTS

Your LaserOp has been specially designed as a professional tool, to be used by a trained, 
qualifi ed, and specifi cally designated specialist (preferably certifi ed/authorised internally at 
the operator’s organisation). 
The LaserOp is intended to be used outdoors only.
The LaserOp is appropriate to scare birds away, from a close range up to a distance of 2 km 
(~1 mile), depending on the environmental conditions. The LaserOp’s effi ciency is at its best 
on darker days (e.g. during winter) or at sunrise/sunset, when the birds are most active.
The LaserOp is powered through batteries.
The LaserOp has proven to be successful in many different situations, scaring away all kinds 
of nuisance causing birds. It is effi cient on farm fi elds, horticulture plots, cereal storing 
facilities, cattle stables, country estates, landfi lls and industrial properties. 
A frequent usage of the LaserOp will cause the birds to return less quickly after they were 
scared away.

 

The laser is to be operated with the smallest possible beam.

2.2 

SYMBOLS WITHIN THIS INSTRUCTION MANUAL AND ON THE LASEROP

SYMBOL

MEANINg

SYMBOL

MEANINg

Take care! 
Important instruction 
within the Instruction 
Manual

Reading the
Instruction Manual is 
mandatory

Class 3b laser beam

Label on the LaserOp:

Laser beam window

“Never look into 

the laser beam and 

never point the beam 

towards persons”

Label on the LaserOp:

Laser beam

“Never look into 

the laser beam and 

never point the beam 

towards persons”

“Class 3B Laser 

Device”

4

Summary of Contents for LaserOP 3.0

Page 1: ...Instruction manual To scare birds with a laser beam 2017 Im en Export Frijters Rijsbergen B V Translated Instruction Manual Version 2 1 2017...

Page 2: ...ined qualified operator user 6 3 2 Information and safety requirements for class 3b laser devices 7 3 3 Residual risks 8 4 USE AND OPERATION 9 4 1 Inserting the batteries 9 4 2 Powering up the LaserOp...

Page 3: ...the Operating and Safety Instructions it contains at any time Operating the LaserOp is ONLY allowed if this Instruction Manual is thoroughly known and understood The operator should respect all Usage...

Page 4: ...uccessful in many different situations scaring away all kinds of nuisance causing birds It is efficient on farm fields horticulture plots cereal storing facilities cattle stables country estates landf...

Page 5: ...2 3 LaserOp case and contents 2 4 LaserOp device description 5...

Page 6: ...ioning setup operating cleaning and servicing of the LaserOp can only be performed by specially trained personnel A guaran teed internal certification authorisation at the operator s organisation is n...

Page 7: ...HD In the Netherlands the operator should comply with the requirements listed in sections 6 12 6 26 and 6 27 of the ARBO resolution In Belgium the user should consider the public health laws The resid...

Page 8: ...er beam when you are at less than 1 016 metres 0 65 miles from the device as this would cause serious eye damage If you accidentally do look into the beam seek immediate medical attention in order to...

Page 9: ...could be within the reach of the laser beam 1 Power up the LaserOp with the ON OFF key switch located in the middle of the end cap 2 Next push the main switch the control light turns on 3 As soon as...

Page 10: ...wards the birds or just above them Normally the birds will immediately flee to a nearby hiding place follow them with the beam to scare them away from their hiding place If this is regularly done the...

Page 11: ...11...

Page 12: ...of the battery compartment the LaserOp may never be opened by the user The device should be stored in a dry and dust free area at constant ambient temperature Getting started The LaserOp has the IP 52...

Page 13: ...ijsbergen B V reserves the right to change the above men tioned technical data as a result of the ongoing innovative development of the LaserOp without prior notification Furthermore the technical dat...

Page 14: ...6 FAULTS OVERVIEW 14...

Page 15: ...rOp Year Built 2017 Applied EC directive EMC Directive 2014 30 EU Applied Standards EN IEC 60529 1992 A1 2000 Degrees of protection provided by enclosures IP Code EN IEC 60825 1 2014 Safety of laser p...

Page 16: ...Im en Export Frijters Rijsbergen B V Smokstraat 2 4891 ZK Rijsbergen NL The Netherlands Phone 0031 0 6 51 35 34 47 E mail info ketrop com 8 CONTACT DETAILS OF MANUFACTURER 16...

Reviews: