Electrical connection
Installation of the induction hob should be performed by specialized personnel and carried out in compliance
with current regulations. Make sure that the parts in tension underneath the hob are protected. The outline for
the electrical connection is indicated on the label near the terminal board. In case of direct connection to the
network it will be necessary to interpose an omnipolar switch with a minimum opening between the contacts
of 3 mm. Connection to the electrical network must be separated by the appropriate interruption: switch, fuse.
Always connect the earthing cable.
Comply with the connection instructions.
The terminal board is located under the hob at the back. Use a screwdriver to
open the cover of the terminal board.
Connecting cable to hob
With respect to the various types of connection, you should utilize the appropriate jumpers placed inside the
jumper board.
MONOPHASE: connect the jumper provided between clamps 1-2. The phase should be connected to clamp 1
or 2. The neutral should be connected to clamp 4
2 N: connect the neutral to clamp 4, one phase to clamp 1 and one phase to clamp 2
EARTHING: the earthing cable should be connected to the appropriate clamp.
Electrical cable table
POWER
CONNECTIONS
WIRING
TYPE OF WIRING
FUSE
230V a.c. 1P+N 50Hz
1 phase + N
3 x 2,5 mm
2
H05RR
25 A*
400V a.c. 2P+N 50Hz
2 phase + N
4 x 1,5 mm
2
H05RR
16 A*
(*) calculated using the coincidence factor 60 335-2-6
The manufacturer will not be held liable for any damages due to improper electrical connections