Ilumipod 7 IP Optic RGBW QRG 

 

DMX Control 

 

You will be able to control this product using a standard DMX controller. 
The Ilumipod 7 IP Optic RGBW is set by default to the 7-channel 

ARC 

FULL

 DMX personality and its DMX address is 

001

. The connections for 

the DMX cables are indicated below.  

To change the DMX personality, DMX address, or any other parameter of 
the Ilumipod 7 IP Optic RGBW, you will need to use the optional Ilumicode 
unit  (see Settings on page 5). 

   

 

DMX 

Connection 

 

You can connect the bare-ended IP67 rated signal cable from the fixture to 
an IP67 junction box, as shown below.  

Make sure to use IP67 rated conduit or direct buried cable (DBC) to link the 
junction boxes. 

   

 

DMX Junction Box 

Wiring 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

Summary of Contents for Ilumipod 7

Page 1: ...I Il lu um mi ip po od d 7 7 I IP P O Op pt ti ic c R RG GB BW W Quick Reference Guide...

Page 2: ...fixture overhead without using a safety cable DO NOT submerge this product at more than 1 m and or for longer than 30 minutes IP67 rating Regular outdoor operation is fine DO NOT operate this fixture...

Page 3: ...he light to the base is adjustable and it can swivel thus providing full angle control A spike is included for mounting this product on soil gardens and large flowerpots Mounting Diagram AC Power This...

Page 4: ...for the DMX cables are indicated below To change the DMX personality DMX address or any other parameter of the Ilumipod 7 IP Optic RGBW you will need to use the optional Ilumicode unit see Settings on...

Page 5: ...unit to each fixture individually This means that you will also have to disconnect the DMX output of the fixture under configuration if there are other fixtures connected to it Ilumicode Connection D...

Page 6: ...d increases the numeric value when in a function DOWN Navigates downwards through the menu options and decreases the numeric value when in a function Menu Options 1st Level Programming Levels Descript...

Page 7: ...5 236 240 241 245 246 250 251 255 No function R 100 G Up B 0 R Down G 100 B 0 R 0 G 100 B Up R 0 G Down Be 100 R Up G 0 Be 100 R 100 G 0 B Down R 100 G Up B Up R Down G Down B 100 R 100 G 100 B 100 W...

Page 8: ...C Brookhill Road Industrial Estate Pinxton Nottingham UK NG16 6NT Voice 44 0 1773 511115 Fax 44 0 1773 511110 Technical Support Email Eutech chauvetlighting eu World Wide Web www chauvetlighting eu Te...

Reviews: