background image

 

Ilumipanel 90 IP Optic RGBWA 

 

User Manual 

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for Ilumipanel 90

Page 1: ...Ilumipanel 90 IP Optic RGBWA User Manual...

Page 2: ...f this manual or its content for any other purpose without its written consent Document Printing For better results print this document in color on letter size paper 8 5 x 11 inches double sided If us...

Page 3: ...on 6 Mounting 6 Orientation 6 Installation 6 AC Power 7 Power Consumption 7 AC Plug 7 Power Wiring 7 DMX Linking 8 DMX Modes 8 Signal Wiring 8 Protocol Connectivity 8 Controllers 9 DMX Controller 9 IL...

Page 4: ...ual Rev 10 5 Technical Information 18 Product Maintenance 18 Product Repairs 18 Troubleshooting Guide 19 Photometrics 20 LED Disclaimer 21 LED Life 21 LED Binning 21 Color Rendering Index CRI 21 Retur...

Page 5: ...ck the contents to ensure that all parts are present and in good condition Claims The carrier is responsible for any damage incurred during shipping If the merchandise appears to have been damaged dur...

Page 6: ...rce before servicing Always connect this product to a grounded circuit to avoid the risk of electrocution Do not touch this product s housing when operating because it may be very hot Mounting and Ins...

Page 7: ...put are located on the power supply Features 1 3 4 5 6 7 or 9 channel DMX 512 LED array light Operating modes 1 channel Dimmer 3 channel RGB control 4 channel Dimmer RGB control 4 channel RGBW control...

Page 8: ...t Description 4 Ilumipanel 90 IP Optic RGBWA User Manual Rev 10 Product Overview Locking Adjustment Plate 316 Stainless Steel Gland Nuts Position Locking Pin Power In Signal In Out Gore Valve W DMX An...

Page 9: ...Product Description Ilumipanel 90 IP Optic RGBWA User Manual Rev 10 5 Product Dimensions...

Page 10: ...uration and maintenance Installation The Ilumipanel 90 IP Optic RGBWA has twelve 12 mounting points on the base of the product to secure to almost any surface ILUMINARC recommends following the genera...

Page 11: ...input voltage range of 100 240 VAC 50 60 Hz Make sure you are connecting this product to the proper voltage as per the specifications in this manual or on the product s sticker Power Consumption To d...

Page 12: ...dividually with a single DMX controller DMX Modes The Ilumipanel 90 IP Optic RGBWA uses the standard DMX data connection for ARC1 ARC1 D ARC2 ARC2 D ARC3 ARC3 D ARC FULL REMOTE SOLID and SPECIAL 2 Ref...

Page 13: ...tions to operate these products with each of the above controllers are in the Operation chapter of this manual You may also choose to connect these controllers via W DMX Refer to the W DMX transmitter...

Page 14: ...o work with the ILUMICON controller instead of a standard DMX controller Please refer to the ILUMICON User Manual to learn how to use this controller with the Ilumipanel 90 IP Optic RGBWA products The...

Page 15: ...aired with the W DMX transmitter Use the following instructions to operate 1 Using the Ilumicode set the personality and the DMX address to the Ilumipanel 90 IP Optic RGBWA Refer to the programming se...

Page 16: ...menu options relate to each other Use ENTER and MENU to change levels in the Menu Map This is equivalent to move right and left respectively Use UP and DOWN to move vertically within the Menu Map opti...

Page 17: ...ETTINGS COLOR 2 Select the color method OFF RGB TO W UC Procedure OFF When the RGB faders are all set to 255 the output is maximum RGB TO W When the RGB faders are all set to 255 the output is the sel...

Page 18: ...unit SOLID 1 channel dimmer SPECIAL 2 9 channel RGBWA control dimmer color macro strobe dimmer speed CALIB WHITE 1 11 RED GREN BLUE COOL WARM AMBE 0 255 Determines the white balance for the color macr...

Page 19: ...R 0 G Down B 100 R Up G 0 B 100 R 100 G 0 B Down R 100 G Up B Up R Down G Down B 100 White 1 3 200 K White 2 3 400 K White 3 4 200 K White 4 4 900 K White 5 5 600 K White 6 5 900 K White 7 6 500 K Whi...

Page 20: ...255 0 100 ARC 3 Channel Function Value Percent Setting 1 Red 000 255 0 100 2 Green 000 255 0 100 3 Blue 000 255 0 100 4 White 000 255 0 100 5 Amber 000 255 0 100 ARC 3 D Channel Function Value Percent...

Page 21: ...86 210 211 215 216 220 221 225 226 230 231 235 236 240 241 245 246 250 251 255 No function R 100 G Up B 0 R Down G 100 B 0 R 0 G 100 B Up R 0 G Down B 100 R Up G 0 B 100 R 100 G 0 B Down R 100 G Up B...

Page 22: ...To clean a product follow the below recommendations Disconnect the product from power Wait until the product has cooled Use a vacuum or dry compressed air and a soft brush to remove dust collected on...

Page 23: ...a short in the electrical wiring Product does not power up No power Check for power on power outlet Loose or damaged power cord Check power cord Faulty internal power supply Return for service to Ilum...

Page 24: ...ens lamp 1500 Max Candela 6 068 5 at Horizontal 0 Vertical 3 Input Wattage 297 3 Luminous Opening Point Test 20101207RGBWA30 Test Lab Iluminarc R D Optics Laboratory Photometry Type B CIE Class Direct...

Page 25: ...limitations and inconsistencies related to CRI Results may vary depending on the environmental factors involved For this reason the US Department of Energy DOE states that CRI should be considered as...

Page 26: ...and a brief description of the cause for the return The user must clearly label the package with a Return Merchandise Authorization Number RMA ILUMINARC will refuse any product returned without an RMA...

Page 27: ...60 Hz 230 V 50 Hz Consumption 312 W 2 6 A 296 W 1 4 A Power I O Input Output Connectors Hard wired N A Cord plug Open ended N A Light Source Type Power Current Lifespan LED 5 W 700 1000 mA 50 000 hou...

Page 28: ...Technical Information ILUMINARC 5200 NW 108th Avenue Sunrise FL 33351 U S A Tel 954 923 3680 www iluminarc com Ilumipanel 90 IP Optic RGBWA User Manual Rev 10 November 2011...

Reviews: