background image

Ilumipanel 180 IP Optic RGB QRG 

 

10 

DMX Values 

 

ARC FULL 

 

Channel  Function 

Value 

Percent/Setting 

Dimmer 

000 

ó

 255  0~100% 

Red  

000 

ó

 255  0~100%  

Green  

000 

ó

 255  0~100%  

Blue 

000 

ó

 255  0~100% 

Color Macros 

000 

ó

 010 

011 

ó

 030 

031 

ó

 050 

051 

ó

 070 

071 

ó

 090 

091 

ó

 110 

111 

ó

 130 

131 

ó

 150 

151 

ó

 170 

171 

ó

 200 

201 

ó

 205 

206 

ó

 210 

211 

ó

 215 

216 

ó

 220 

221 

ó

 225 

226 

ó

 230 

231 

ó

 235 

236 

ó

 240 

241 

ó

 245 

246 

ó

 250 

251 

ó

 255 

No Function 
R: 100%  

G: 0~100% 

B: 0% 

R: 100~0%  G: 100%  

B: 0% 

R: 0% 

G: 100% 

B: 0~100% 

R: 0%  

G: 100~0%   B: 100% 

R: 0~100%  G: 0%  

B: 100% 

R: 100%  

G: 0%  

B: 100~0% 

R: 100% 

G: 0~100%   B: 0~100% 

R: 100~0%  G: 100~0% 

B: 100% 

R: 100%  

G: 100% 

B: 100% 

White 1 
White 2 
White 3 
White 4 
White 5 
White 6 
White 7 
White 8 
White 9 
White 10 
White 11 

Strobe 

000 

ó

 009 

010 

ó

 255 

No Function 
Slow~Fast 

Dimmer Speed 

000 

ó

 009 

010 

ó

 029 

030 

ó

 069 

070 

ó

 129 

130 

ó

 189 

190 

ó

 255 

Uses Ilumicode Settings  
Off 
Speed 1 (Fastest) 
Speed 2 
Speed 3 
Speed 4 (Slowest) 

 
 

 

Summary of Contents for Ilumipanel 180

Page 1: ...Ilumipanel 180 IP Optic RGB Quick Reference Guide ...

Page 2: ...erviceable parts DO NOT look at the light source when the product is on DO NOT touch the product when operating because it may be hot DO NOT leave any flammable material within 50 cm from the product while operating or connected to the power outlet to minimize the risk of fire DO NOT mount the product overhead without using a safety cable DO NOT submerge this product IP66 Regular outdoor operation...

Page 3: ...mer speed Five distinct dimming curves Dual Vector Array LED panel positioning High power 5 W 700 1 000 mA RGB LEDs IP66 with 316 stainless steel hardware GORE valve Cast and extruded aluminum with Integrated Cooling Enhancement Options Ilumicode addresser for product configuration The RDM2go which includes a built in Ilumicode addresser along with many other useful features is now available The I...

Page 4: ...t the bare ended IP66 rated power cable from the product to an IP66 rated power connector Use an IP66 rated junction box If so make sure to use IP66 rated conduit Iluminarc recommends always using conduit for underground wiring of any kind Power Cable Table Connection Wire US Wire Europe IP66 Pin AC Live Black Brown 1 AC Neutral White Blue 2 AC Ground Green Yellow Green Yellow 3 AC Power Junction ...

Page 5: ...P6 rated signal cable from the product to two IP66 rated signal connectors DMX In and DMX Out Use an IP66 rated junction box If so make sure to use IP66 rated conduit The signal cable must match or exceed the electrical characteristics of the Belden 9841 cable for EIA RS 485 applications You can also use CAT 5 CAT 5e or CAT 6 DMX Junction Box Wiring DMX Cable Table Connection DMX In DMX Out IP66 P...

Page 6: ...to connect the Ilumicode to the product This connection will control multiple products at the same time In addition all connected products will be assigned to the same DMX address To assign individual DMX addresses to each product connect the Ilumicode unit to each product individually In addition disconnect the DMX output of the product being configured if other products are connected to it You m...

Page 7: ...80 IP Optic RGB QRG 7 Mounting Before mounting this product read the Safety Notes at the beginning of the Ilumipanel 180 IP Optic RGB User Manual and follow the mounting procedures Mounting Diagram Mounting Points ...

Page 8: ...nu or sets the currently selected value into the selected function UP Navigates upwards through the menu options and increases the numeric value when in a function DOWN Navigates downwards through the menu options and decreases the numeric value when in a function Start Address To ensure full access to all channels in each DMX mode the highest recommended DMX addresses are as follows Mode Address ...

Page 9: ... CALIB WHITE 1 11 RED GREN BLUE 0 255 Determines the white balance for the color macros RGBTOW Determines the white balance when RGBTOW is active DIMMER OFF N A Dimmer works in linear mode DIM 1 Dimmer works in non linear mode from fast to slow DIM 2 DIM 3 DIM 4 STATIC RED 0 255 Configures the static color and effect GREN BLUE STRB 0 20 SETTINGS COLOR OFF Maximum output unbalanced white RGBTOW Whi...

Page 10: ... 221 ó 225 226 ó 230 231 ó 235 236 ó 240 241 ó 245 246 ó 250 251 ó 255 No Function R 100 G 0 100 B 0 R 100 0 G 100 B 0 R 0 G 100 B 0 100 R 0 G 100 0 B 100 R 0 100 G 0 B 100 R 100 G 0 B 100 0 R 100 G 0 100 B 0 100 R 100 0 G 100 0 B 100 R 100 G 100 B 100 White 1 White 2 White 3 White 4 White 5 White 6 White 7 White 8 White 9 White 10 White 11 6 Strobe 000 ó 009 010 ó 255 No Function Slow Fast 7 Dimm...

Page 11: ...55 0 100 5 Module 2 Green 000 ó 255 0 100 6 Module 2 Blue 000 ó 255 0 100 ARC 1 Channel Function Value Percent Setting 1 Red 000 ó 255 0 100 2 Green 000 ó 255 0 100 3 Blue 000 ó 255 0 100 ARC D Channel Function Value Percent Setting 1 Dimmer 000 ó 255 0 100 2 Red 000 ó 255 0 100 3 Green 000 ó 255 0 100 4 Blue 000 ó 255 0 100 SOLID Channel Function Value Percent Setting 1 Master Dimmer 000 ó 255 0 ...

Page 12: ...ghting eu Chauvet France Address 3 Rue Ampère 91380 Chilly Mazarin France Voice 33 1 78 85 33 59 Email Eutech chauvetlighting com Website www chauvetlighting eu Chauvet Germany Address Bruno Bürgel Str 11 28759 Bremen Germany Voice 49 421 62 60 20 Email Eutech chauvetlighting com Website www chauvetlighting eu Chauvet Mexico Address Av de las Partidas 34 3B Entrance by Calle 2 Zona Industrial Lerm...

Reviews: