Ilumipanel 90 IP Optic RGB

 

User Manual 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for Ilumipanel 180 IP Optic 15 RGB

Page 1: ...Ilumipanel 90 IP Optic RGB User Manual...

Page 2: ...ng of this manual or its content for any other purpose without its written consent Document Printing For better results print this document in color on letter size paper 8 5 x 11 in double sided If us...

Page 3: ...6 Installation 6 AC Power 7 Power Consumption 7 AC Plug 7 Power Wiring 7 DMX Linking 8 DMX Modes 8 Signal Wiring 8 Protocol Connectivity 8 W DMX Calibration 9 Controllers 10 DMX Controller 10 ILUMICON...

Page 4: ...lumipanel 90 IP Optic RGB User Manual Rev 01 Troubleshooting Guide 18 Photometrics 19 LED Disclaimer 20 LED Life 20 LED Binning 20 Color Rendering Index CRI 20 Returns Procedure 21 Contact Us 21 Techn...

Page 5: ...e that all parts are present and that they are in good condition Claims The carrier is responsible for any damage incurred during shipping Therefore if the received merchandise appears to have been da...

Page 6: ...cing Always connect this product to a grounded circuit to avoid the risk of electrocution Do not touch this product s housing when operating because it may be very hot Mounting and Installation This p...

Page 7: ...unit The panel is attached to steel arms that are connected to the base The DMX and power input output are located on the power supply Features 1 3 4 or 7 channel RGB LED array light Operating modes 1...

Page 8: ...Product Description 4 Ilumipanel 90 IP Optic RGB User Manual Rev 01 Product Overview Position Locking Pin Mounting Points Locking Adjustment Plate 316 Stainless Steel Gland Nuts W DMX Antenna...

Page 9: ...Product Description Ilumipanel 90 IP Optic RGB User Manual Rev 01 5 Product Dimensions Front View Side View Bottom View...

Page 10: ...intenance Installation The Ilumipanel 90 IP Optic RGB has twelve 12 mounting points on the base of the product to secure it to almost any surface provided that it can support the product s weight ILUM...

Page 11: ...sumption To determine the power requirements for the Ilumipanel 90 IP Optic RGB refer to the label affixed to the side of the product Alternatively you may refer to the Technical Specifications The li...

Page 12: ...single DMX controller If you are not familiar with the DMX standard or if you need information about the DMX cables needed to link the Ilumipanel 90 IP Optic RGB to a DMX controller download the DMX P...

Page 13: ...W DMX transmitter For wireless operation the W DMX receiver in the Ilumipanel 90 IP Optic RGB must be paired with the W DMX transmitter Use the following instructions to operate 1 Using the ILUMICODE...

Page 14: ...DDRESSER The sections below provide information on how to connect these products to the corresponding controllers The instructions to operate these products with each of the above controllers are in O...

Page 15: ...ICON controller ILUMICON The Ilumipanel 90 IP Optic RGB can also work with the ILUMICON controller instead of a standard DMX controller Please refer to the ILUMICON User Manual to learn how to use thi...

Page 16: ...0 m Otherwise you might need to use an optically isolated signal amplifier ILUMICODE ADDRESSER The Ilumipanel 90 IP Optic RGB uses the ILUMICODE ADDRESSER Ilumicode for configuration purposes The diag...

Page 17: ...anel Refer to the Menu Map section to learn how the menu options relate to each other Use ENTER and MENU to change levels in the Menu Map moving right and left respectively Use UP and DOWN to move ver...

Page 18: ...near slow DIM4 Non linear slowest Color 1 Go to SETTINGS COLOR 2 Select the color method OFF RGB TO W or UC Details OFF When the RGB faders are all set to 255 the output is maximum RGB TO W When the R...

Page 19: ...dimmer CALIB WHITE 1 11 RED GREN BLUE 0 255 Determines the white balance for the color macros RGBTOW Determines the white balance when RGBTOW is active DIMMER OFF N A Dimmer works in linear mode DIM...

Page 20: ...0 G 0 B 100 R 100 G 0 B 100 0 R 100 G 0 100 B 0 100 R 100 0 G 100 0 B 100 R 100 G 100 B 100 White 1 White 2 White 3 White 4 White 5 White 6 White 7 White 8 White 9 White 10 White 11 6 Strobe 000 009 0...

Page 21: ...undings can cause greater accumulation of dirt on the product s optics requiring more frequent cleaning To clean a product Unplug the product from power Wait until the product has cooled Use a vacuum...

Page 22: ...power up No power Check for power on power outlet Loose or damaged power cord Check power cord Faulty internal power supply Return for service to ILUMINARC Product does not respond to DMX Wrong DMX ad...

Page 23: ...ted Lumens lamp 2000 Max Candela 35 453 7 at Horizontal 0 Vertical 0 Input Wattage 284 Luminous Opening Point Test 2011 ALL Test Lab Iluminarc R D Optics Laboratory Photometry Type B CIE Class Direct...

Page 24: ...nd inconsistencies related to CRI Results may vary depending on the environmental factors involved For this reason the U S Department of Energy DOE states that CRI should be considered as one point of...

Page 25: ...ust clearly label the package with an RMA ILUMINARC will refuse any product returned without an RMA DO NOT write the RMA directly on the box Instead write it on a properly affixed label Once you recei...

Page 26: ...z Consumption 307 W 2 5 A 279 W 1 3 A Power I O Input Output Connectors Hard Wired N A Cord plug Open Wire N A Light Source Type Power Lifespan LED 5 W 50 000 hours Color Quantity Current Red 30 700 m...