B. Adjusting light sensor sensitivity
The factory setting value of “Light Sensor Sensitivity” is at level 6. However, the user may change
the sensitivity setting manually as below;
▪
Preparation
- 3mm metric hexagonal wrench
- Philips head screwdriver with a small tip
▪
Procedure
-
Remove button head screw with the 3mm metric hexagonal wrench.
-
Photo diode sensitivity trimmer should be exposed through the hole.
Clockwise rotation for less sensitivity (Unit automatically turns-on at darker ambient lighting)
-
Using Philips head screwdriver, turn the trimmer to desired setting.
-
Assemble button head screw back to its original position
Button head screw
Photo diode sensitivity trimmer