background image

Pg. 13

TB-PMP

COLD WEATHER OPERATION

MILWAUKEE Li-Ion battery packs are designed to operate in temperatures below freezing. When 

the battery pack is too cold, it may need to warm up before normal use. Put the battery on a tool 

and use the tool in a light application. It may buzz for a short time until it warms up. When the 

buzzing stops, use the tool normally.

 

         To reduce the risk of fire, personal injury, and product damage due to a short circuit, 

never immerse your tool, battery pack or charger in fluid or allow a fluid to flow inside them. 

Corrosive or conductive fluids, such as seawater, certain industrial chemicals, and bleach or bleach 

containing products, etc., can cause a short circuit.

MAINTENANCE AND STORAGE

Do not expose your battery pack or cordless tools to water or rain, or allow them to get wet. This 

could damage the tool and battery pack. Do not use oil or solvents to clean or lubricate your 

battery pack. The plastic casing will become brittle and crack, causing a risk of injury. Store battery 

packs at room temperature away from moisture. Do not store in damp locations where corrosion 

of terminals may occur. As with other battery pack types, permanent capacity loss can result if the 

pack is stored for long periods of time at high temperatures (over 120° F). MILWAUKEE Li-Ion 

battery packs maintain their charge during storage longer than other battery pack types. After 

about a year of storage, charge the pack as normal. 

TRANSPORT

Personal transport of Li-Ion battery packs is allowed when done in accordance with these 

warnings and instructions. The proper classification, packaging, labeling, marking, and 

documentation requirements for shipping Li-Ion batteries is dependent upon whether the 

particular batteries is dependent upon whether the particular batteries are rated greater than or 

less than 100 Wh. Li-Ion batteries rated 100 Wh or less are typically exempt from certain Class 9 DG 

requirements. Always check compliance of Li-Ion battery consignments against the regulations 

governing the mode of transport. When in doubt, contact the carrier or other trained 

Dangerous Goods professional to confirm acceptability. Li-Ion packs are shipped under 

classification UN 3480 (battery only) or UN 3481 (batteries contained in or packed with equipment). 

 To reduce the risk of injury or explosion, never burn or incinerate a battery pack 

even if it is damaged, dead, or completely discharged. When burned, toxic fumes and materials are 

created.

DISPOSING OF MILWAUKEE LI-ION BATTERY PACKS

MILWAUKEE Li-Ion battery packs are more environmentally friendly than other types of power tool 

battery packs (e.g., nickel-cadmium). Always dispose of battery pack according to federal, state, 

and local regulations. Contact a recycling agency in your area for recycling locations. Even dischar-

ged battery packs contain some energy. Before disposing, use electrical tape to cover the terminals 

to prevent the battery pack from shorting, which could cause a fire or explosion. 

RBRC BATTERY RECYCLING SEALS

The RBRC™ Battery Recycling Seals (see Symbology) on your tool battery pack indicates that 

MILWAUKEE has arranged for the recycling of that battery pack with the Rechargeable Battery 

Recycling Corporation (RBRC). At the end of the battery pack‘s useful life, return it to a MILWAUKEE 

Branch Office/Service Center or the participating retailer nearest you. For more information, visit 

the RBRC web site at www.rbrc.org.

Summary of Contents for TaskMaster TB-PMP

Page 1: ...P Read and understand all of the instructions and safety information in this manual before operating or servicing this tool TaskMaster from ILSCO 4730 Madison Road Cincinnati OH 45227 www ilsco com Ph...

Page 2: ...Parts Breakdown Page 20 13 Parts List Page 21 14 Software Installation Page 22 THANK YOU for buying an ILSCO TaskMaster Tool Our mission is to bring product innovation and exceptional customer service...

Page 3: ...needs ILSCO tool owners will be offered options to solve any tool replacement parts or repair issues Call 513 533 6200 or 800 776 9775 Monday to Friday 8 00AM to 5 00PM Eastern Time ET MILWAUKEE BATT...

Page 4: ...pment Always wear eye protection Protective equipment such as a dust mask non skid safety shoes hard hat or hearing protection for appropriate conditions will reduce personal injuries Do not overreach...

Page 5: ...risk of injury and fire When battery pack is not in use keep it away from other metal objects like paper clips coins keys nails screws or other small metal objects that can short circuit from one ter...

Page 6: ...icator lights Return adjustment knob Shoulder strap connector Label Remote pump cord Remote connection Hydraulic connection 3 Pump Parts Identification Battery compartment Oil cap USB interface Air Fi...

Page 7: ...B PMP 4 Kit Includes 1 Battery Powered Pump 2 Milwaukee 5 0 Ah Batteries 1 Milwaukee 120V Charger 1 Shoulder Strap 1 Bag 1 Remote Pump Cord 1 Non Conductive Hose 1 USB Cable 1 Male Adapter 1 Female Ad...

Page 8: ...apacity 5 0 Ah Type of battery Lithium ion Charging time 60 min approx Hydraulic oil Shell Tellus S2 V 15 Oil capacity 25 oz 45 1 in3 Operating temperature range 14 F to 104 F Dimensions 11 6 in x 8 1...

Page 9: ...harging is complete Fast flashing red Battery is too hot cold Charging will begin when battery reaches correct charging temperature Slow flashing red Battery charge is pending Charging will begin when...

Page 10: ...ully discharged battery pack with an internal temperature in the normal range will charge in about 30 to 185 minutes depending on the battery pack Heavily cycled batteries may take longer to charge co...

Page 11: ...able parts MOUNTING TO THE WALL Use the wall mount guides to mark the hanging points To reduce the risk of injury always unplug the charger and remove the battery from the charger before performing an...

Page 12: ...r 2 3 seconds and the tool will not run Charge the battery pack NOTE Immediately after using the battery pack the Fuel Gauge may display a lower charge level Recheck a few minutes later for a more acc...

Page 13: ...ing marking and documentation requirements for shipping Li Ion batteries is dependent upon whether the particular batteries is dependent upon whether the particular batteries are rated greater than or...

Page 14: ...Pg 14 TB PMP 9 Pump Setup 1 Attach shoulder strap by rotating connecting clip and pulling down until it locks in place 2 Remove cover from remote port and attach remote cord...

Page 15: ...Pg 15 TB PMP 3 Remove hydraulic fitting cap on pump and attach hydraulic hose to pump 4 Attach hydraulic hose to head...

Page 16: ...t battery into opening at rear of pump by squeezing battery side buttons and pushing battery in Battery will click into place 2 To remove battery squeeze side buttons and pull battery out TURNING THE...

Page 17: ...art up and flashes slowly ON GREEN LED comes on when work cycle is complete RED LED comes on when work cycle is not complete RED GREEN LED flashes when service is due UNDERSTANDING PUMP DISPLAY Operat...

Page 18: ...ete your cycle and retract to set position If the dial is set to 0 the pump will stop once the cycle is complete and will require manual retraction using the remote control unit The service light LED...

Page 19: ...ting head jaws free of metal shavings Wipe down all steel parts with WD 40 Do not store the tool in a humid environment The tool should provide many years of service when given the proper maintenance...

Page 20: ...Pg 20 TB PMP 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 3 3 3 5 5 5 2 2 2 14 7 7 7 7 12 Tool Parts Breakdown...

Page 21: ...crew 5 8 711265 Filter 1 9 714644 Shell Back 1 10 714647 Air Discharge Aperture 1 11 711262 Mandrel Short 1 12 715292 Pressure Release Lever 1 13 711401 Bolt 1 14 711263 Mandrel Long 3 15 711270 Grab...

Page 22: ...ows XP Windows Vista Windows 7 CPU Pentium 4 at least 1 7 GHz Memory 512MB or more 1 GB or more recommended Hard Drive 200 MB 1 GB recommended Screen resolution 1024 x 768 or higher at least 65 535 co...

Page 23: ...Pg 23 TB PMP Notes...

Page 24: ...Service Date 07 17 Version 1 TaskMaster from ILSCO 4730 Madison Rd Cincinnati OH 45227 Phone 800 776 9775 513 533 6200 www ilsco com...

Reviews: