![iLO IHP2424 User And Installation Manual Download Page 6](http://html1.mh-extra.com/html/ilo/ihp2424/ihp2424_user-and-installation-manual_2044219006.webp)
6
ILO North America
•
5410 West Roosevelt Road
•
Unit 205
•
60644
•
Chicago
•
Phone: +1(312) 508 8600
•
Website: http://www.ilo-international.com/
1
Size -
Denotes the actual size when cold. At operating temperature these dimensions will vary slightly.
The IHP2424 and IHP4824 panels are standardized dimensions designed for dropped or
suspended ceiling installations. The IHP4141 panel can be mounted on a ceiling or wall using the
special mounting brackets supplied. This panel is not designed for use in a dropped ceiling.
2
Weight -
This value will help in choosing suitable anchor fasteners.
3
Mounting Type -
“A”, “B”, and “C” refer to the mounting hole spacing for the brackets. See page 10
for more information.
Rating Class
Model
IP Rating
1
Protection Class
2
IR Spectrum
3
IHP2424
30
Class I
IR-C 7,980nm
IHP4824
30
Class I
IR-C 7,980nm
IHP4141
30
Class I
IR-C 7,980nm
1
IP Rating
- According to the International Protection Rating system, ILO Heating Panels are
rated at
IP30.
This means they are mechanically protected against solid objects greater than
2.5mm (0.10”) causing harm to the heater but have no protection against water spray. These
heating panels are designed for indoor use in non-wetted areas.
2
Protection Class
- The ILO Heating Panels are rated as a
Class I
appliance. This means the
aluminum frame is connected to electrical earth (ground). If a live conductor contacts the frame
then current will flow through the earth (ground) conductor and will either trip the circuit breaker
or the RCD (GFCI) if fitted.
3
Infrared Spectrum
- The type of IR energy released by the heater panel is classed as being in
the Far Infra-Red, Long wavelength Infra-Red, or
IR-C
area of the spectrum, according to the
limits defined by the International Commission on Illumination. Referring to Wien’s
Displacement Law, it can be proven that a body with a surface temperature of 90°C (363 K)
emits energy with a wavelength of approximately 8.0 microns. Refer to page 19 for more
information.
Environmental Conditions
Model
Max. Ambient
Temperature
1
Max. Ambient
Humidity (RH)
2
Operating
Temperature
3
IHP2424
104°F (40°C)
85%
194°F (90°C)
IHP4824
104°F (40°C)
85%
194°F (90°C)
IHP4141
104°F (40°C)
85%
194°F (90°C)