background image

Basic Safety Instructions 

Basic Safety Instructions 

2.1 General 

Information 

Warning notices must be observed. Disregarding them may lead to damage to health and 
property. 
The diaphragm pumps must be operated by personnel who can detect impending dangers 
and take action to prevent them from materialising. 
The manufacturer or authorized authorised workshops will only service or maintain the dia-
phragm pump if it is accompanied by a fully completed damage report. Precise information 
about the contamination (also negative information if necessary) and thorough cleaning of 
the diaphragm pump are legally binding parts of the contract. 
Contaminated diaphragm pumps and their individual parts must be disposed of in accor-
dance with the legal regulations. 
The local regulations apply in foreign countries. 
 

2.2 Electricity 

The diaphragm pumps of operation mode S1 are supplied. When the location of operation 
mode S1 devices is changed, please note that the testing must be repeated in accordance 
with DIN EN 0105, DIN EN 0702 and BGV A2. 
The local regulations apply in foreign countries. 
Please note the following when connecting to the electrical power supply system: 

• 

The electrical power supply system must have a protective connector according to DIN VDE 0100-
410 (IEC 60364-4-41). 

• 

The protective connector must not have any breaks. 

• 

The connecting cable must not be damaged. 

 

2.3 Mechanical 

Systems 

Improper use can lead to injuries or material damage. Observe the following instructions:  

• 

Only operate the diaphragm pumps with hoses of the specified dimensions. 

• 

The maximum permissible pressure of 1 bar at the suction connection must not be exceeded. 

• 

Hazardous substances must be separated out as far as this is technically possible before they 
reach the pump. 

• 

External mechanical stresses and vibrations must not be transmitted to the pump. Only use flexible 
NW 8 laboratory hoses for connecting diaphragm pumps. 

• 

The overpressure generated at the pressure port must not exceed 1 bar. 

• 

The pump must not be used to suck up fluids. Lay the exhaust pipe so that it slopes downwards, so 
allowing condensate to flow out of the pump. Collect the condensate and dispose of it in an envi-
ronmentally compatible manner. 

• 

Prevent dyes exuding. 

• 

Maintain a space of least 20 mm between the pump and adjacent parts in order to enable the pump 
to cool. 

 

 

CAUTION ! 

Solid particles in the pumping medium impair the pumping action and can lead to 
damage. Prevent solid particles penetrating into the pump. 

6 4000732 

Summary of Contents for MP 301 E

Page 1: ...Operation Manual Diaphragm pumps 1 headed Types MP 301 E MPC 301 E 4000732 2008 08 19...

Page 2: ...owed without the prior written permission of ILMVAC GmbH All rights under the copyright laws are expressly reserved by ILMVAC GmbH We reserve the right to make changes and amendments ILMVAC GmbH Am Vo...

Page 3: ...m affecting pump parts 9 3 4 Scope of Delivery 9 3 5 Accessories 9 4 Technical Data 10 4 1 Dimensions 10 4 2 Intake Pressure Pumping Speed Diagram 10 4 3 Device Data 11 5 Installation and Operation 12...

Page 4: ...uired to perform the work that has to be done The user must authorize the operating personnel to do the work that has to be done The personnel must have read and understood the complete Operating Manu...

Page 5: ...ration of electrical installations EN 61010 1 Safety for laboratory devices EN 50081 1 2 Electromagnetic compatibility EMC Generic specification Interference resistance for residential business and in...

Page 6: ...cal power supply system The electrical power supply system must have a protective connector according to DIN VDE 0100 410 IEC 60364 4 41 The protective connector must not have any breaks The connectin...

Page 7: ...ribed in chapter 3 4 and if necessary modified Poisonous gases Use a separator when pumping poisonous or harmful gases Prevent such substances from leaking out of the appliance or pump Treat these sub...

Page 8: ...pump chamber Increasing the size of the pump chamber opens the inlet valve while the outlet valve is closed intake process Decreasing the size of the pump chamber ejects the gas through the outlet val...

Page 9: ...PP PP Hose PTFE PTFE Notes PTFE with carbon fibre reinforcement electrically conductive with manufacturer s certificate of electrical conductivity Material resistance to aggressive media see Kunststof...

Page 10: ...chnical Data 4 1 Dimensions 1 Suction connection Hose nozzle DN 8 2 Pressure connection Hose nozzle DN 8 muffler Fig 2 Dimensions 4 2 Intake Pressure Pumping Speed Diagram Fig 3 Intake Pressure Pumpin...

Page 11: ...Frequency different data upon customer request V Hz 230 50 60 115 50 60 generally with motor protection switch switch and plug IEC Power W 180 Operating mode S 1 Type of protection Motor DIN EN 60529...

Page 12: ...be returned in packaging that is suitable for protecting it during transport 5 2 Installation and Connection 1 Set the diaphragm pump on a flat and horizontal surface 2 Remove the protective caps on...

Page 13: ...r humidity 90 Leave the protective elements on the suction and pressure ports Another equally good pro tection may be used 5 5 Scrap Disposal CAUTION The diaphragm pumps must be disposed of in accorda...

Page 14: ...work that is described here and that which is permitted to be done by the user All other maintenance and service work may only be performed by the manufacturer or a dealer authorized by him Beware of...

Page 15: ...sembly assembly WARNING Renew defective parts if necessary Wear protective gloves Parts must be renewed at the intervals stated in this Operating Manual or as speci fied by the user internally Do not...

Page 16: ...be performed by the manufacturer or authorized workshops WARNING The user shall be liable for the consequences of an incorrect damage report or a contaminated pump The statements in the damage report...

Page 17: ...nd seal the leak replace the seals and hoses if necessary Diaphragm pump leaks pipes or hoses Check the hose connections be tween the pump heads replace the hoses and screwed clamping rings if necessa...

Page 18: ...UTION Ilmvac is not liable for any damage caused by the installation of any parts not sup plied by the manufacturer 8 1 Maintenance kit Designation Order no Maintenance kit 402046 The maintenance kit...

Page 19: ...Spare Parts Overview 8 2 Exploded view Fig 5 Exploded view MPC 301 E 4000732 19...

Page 20: ...0678 2 400678 2 8 Motor V 50 60 Hz 0 18 kW 1 826420 826422 1 9 Handle 1 400964 400964 10 Handle bracket 2 400963 400963 11 Pump bracket 1 400962 400962 12 Rubber pad 4 829150 829150 13 Pressure washer...

Page 21: ...ce 1 400678 2 400678 2 8 Motor V 50 60 Hz 0 18 kW 1 826420 826422 1 9 Handle 1 400964 400964 10 Handle bracket 2 400963 400963 11 Pump bracket 1 400962 400962 12 Rubber pad 4 829150 829150 13 Pressure...

Reviews: