Ilumiline Inground Tri-12 IP Optic 25 RGB QRG
4
DMX
Connection
You can connect the bare-ended IP67 rated signal cable from this product to
two IP67 rated signal connectors (DMX in and DMX Out) or use an IP67
rated junction box. If using an IP67 rated junction box, make sure to use
IP67 rated conduit.
Signal Wiring
To provide a signal for this product, you can connect the bare-ended IP67
rated signal cable from the product to two IP67 rated signal connectors
(DMX in and DMX out) or use an IP67 rated junction box. If using an IP67
rated junction box, make sure to use IP67 rated conduit.
The signal cable must match or exceed the electrical characteristics of
the Belden 9841 cable for EIA RS-485 applications. You can also use
CAT 5, CAT 5e, or CAT 6.
DMX Junction
Box Wiring
DMX Cable
Table
Connection
DMX In
DMX Out
IP67 Pin
Ground
Shield
Shield
1
Data -
Black
Green
2
Data +
White
Red
3
Ilumicon and
DMX
Controllers
The Ilumiline Inground Tri-12 IP Optic 25 RGB can operate with either an
Ilumicon or a DMX controller. Use the standard DMX connection, as shown
on page 4 (
DMX Junction Box Wiring
) to connect this product to any of
those controllers. For more information, please refer to the
Ilumiline
Inground Tri-12 IP Optic 25 RGB User Manual
.
Settings
To configure the Ilumiline Inground Tri-12 IP Optic 25 RGB, use the
Ilumicode addresser.