Triax A/T Quick Start Guide
6
B. Select the TRACER TOWER option and press the ENTER button or directly
push the #2 button.
C. The data shown in this box are the adjustments that have been read during pre-
vious calibrations. Before starting the TRACER TOWER calibration, make sure
that there are no keys and/or adapters fitted in the R1 clamp. At this point press
the START button.
D. The screen will display “
INSTALL R1
CLAMP AND LOWER TRACER
”. Lower the
TRACER TOWER using the red ball handle
(1) located on the left side of the Z-axis. The
Z-axis is the vertical axis with the cutter or
decoder loaded into it. (Press START to
begin the automatic procedure for reading
the position of the U103TT (2) tracer point.
E. By pressing the START button, the Triax A/T will automatically start the
calibration of the TRACER TOWER.
F. Once the operation is complete, the screen will show the differences from the
theoretical values. To save the data, press the ENTER button. If the STOP
button is pressed, the new settings will not be saved, and the previous settings
will remain valid.
G. After the calibration is complete, raise the TRACER TOWER by the red ball
handle to the idle position (up).
H. Press the STOP button twice to return to the Triax A/T main menu.
5. Cutting Keys By Duplication
A. Use the
BC
buttons to move the cursor to the
DECODE AND COPY option, and press
ENTER, or directly push the #0 button. This
will open the DECODE AND COPY function.
There are (2) two different options to
DECODE AND COPY:
• To search by SSN (Silca Serial Number)
use the Triax A/T internal card list to select
the appropriate card number. Use the
number and letter buttons, to type this card
number onto the appropriate line, then
press ENTER.
• To search by MFG (Manufacturer), it is
not necessary to enter the entire name;
the first letters are sufficient. Use the
SSN = (Decode)
MFG = Lex
=> Lexus (Toyota)
(2) List = enter
E
EN
NT
TE
ER
R
Lexus (Toyota) (2)
1: TOY40P (4T-8W)
2: TOY48P (4T-5W)
2
1