TM60Pi (06/00)
PAG. 6
Connect the power supply and the receiver outputs on the corresponding relay board
plug-in terminals. Do this following the outputs diagram, which is supplied with the set.
This diagram indicates the connection between the transmitter commands and the
receiver outputs.
The KSTOP1 and KSTOP2 relays are in series and must be connected to the main
contactor coil circuit.
The K2/START is activated once the start-up command is held down.
The K1/SEC relay is a security relay which is activated when certain commands
predefined as “active” on configuration of the set, (i.e. commands which give rise to
manoeuvres), are activated.
Remember to connect the ground cable.
Only use fireproof cables for connections.
Select the appropriate voltage on the receiver, (230, 115 or 48 Vac).