General safety instructions

 

J

Read this entire user manual carefully before plugging in the unit.

 

J

Keep these instructions to hand during unit installation.

 

J

Follow all the instructions and safety notices when handling the uni

DANGER OF DEATH OR INJURY

 

J

This safety notice indicates a potential hazard to people’s lives and/or health. Failure to follow these instructions can lead to severe 

health consequences and may even cause fatal injuries.

 

J

Do not install the unit during electrical storms. This could lead to electro-static discharge from lightning.

 

J

Do not open the unit. You may suffer an electric shock.

RISK OF DAMAGE TO THE UNIT

 

J

This safety notice indicates a potentially hazardous situation. Failure to follow these instructions may cause material damage to the unit.

 

J

Keep the unit well-ventilated at all times. Install the unit in an area free of dust. Do not place the unit in a place where the ventilation 
slots may become blocked or obstructed.  
Leave a distance of at least 20 cm all around the unit’s sides. We recommend installing the unit in the VERTICAL position.

 

J

Do not expose the unit to rain or moisture. Install in a dry location where potential leaks or condensation will not occur. In the event that 
liquid gets into the device, disconnect it immediately from the alternating current.

 

J

Keep flammable objects, candles and anything that may cause a fire away from the unit.

 

J

Connect the unit to an easily-accessible mains outlet, so that the unit can be quickly disconnected from the outlet in case of emergency.

 

J

Do not expose the unit to sources of heat (sunlight, radiators, etc).

DO NOT HANDLE ANY OF THE UNIT’S INTERNAL PARTS

This notice indicates that users should not handle any internal parts that could affect its working order or warranty.

DO NOT DISPOSE OF UNIT AS NORMAL DOMESTIC URBAN WASTE

This type of notice indicates that the unit should not be disposed of as unselected domestic urban waste.

DANGER

ATTENTION

Product installation

LOCATION

 

J

Locate the multiswitch indoors. Do not expose it to rain and direct solar radiation. Fix it to the wall by using suitable screws.

 

J

Ensure a free space of 20 cm (7.8 inch) on each side of the unit, upwards a clearance at least 50 cm (19.7 inch).

 

J

Choose an installation place where there is a possibility in case of emergency to get to mains plug and remove it out of the outlet.

SAFETY

 

J

Do not open the multiswitch; otherwise there is a shock hazard.

 

J

Be sure with sufficient earthing of the aerials and aerial feeds.

CONNECTON

 

J

Take care not to make short-circuits when mounting the F-connectors on the cables.

 

J

Identify the down-lead cables from the LNB. Then interconnect the input marked 12V to the LNB output Vertical. Interconnect the input marked 

18V to the LNB output Hori-zontal. Interconnect the input marked 0kHz to the LNB output Low. Interconnect the input marked 22kHz to the LNB 

output High.

 

J

Before connecting the input and output coaxial cables, disconnect from the mains the multiswitch as well as the receivers and TV sets.

 

J

Not connected outputs of the multiswitch should be terminated with 75Ω terminations..

 

J

Input signal levels may be levelled with the existing variable attenuators. This work requires an appropriate SAT-TV analyzer.

 

J

Active and passive mode of terrestrial band can be selected by the switchs or potentiometer. The return path is available in the passive mode.

The applicable European Standards and national requirements to ensure electrical security have to be obeyed. Likewise national standards and requi-

rements for radio and TV receiving installations.

Summary of Contents for SM Series

Page 1: ...SM Stand alone Multiswitches SMC Cascadable Multiswitches SMU Amplifiers Multiswitches User guide ...

Page 2: ...2 3 Index General safety instructions 4 Product installation 5 1 SM Stand alone Multiswitches 6 2 SMC Cascadable Multiswitches 8 3 Amplifiers 10 4 Power Supply 12 ...

Page 3: ...users should not handle any internal parts that could affect its working order or warranty DO NOT DISPOSE OF UNIT AS NORMAL DOMESTIC URBAN WASTE This type of notice indicates that the unit should not be disposed of as unselected domestic urban waste DANGER ATTENTION Product installation LOCATION J J Locate the multiswitch indoors Do not expose it to rain and direct solar radiation Fix it to the wa...

Page 4: ...SM 1716 Distribución en estrella para 16 usuarios a través de un multiswitch autónomo SM SPS 1820 16 Sat IF polarities plus Terrestrial through SM 1716 stand alone multiswitches MODEL SM 0504 SM 0508 SM 0512 SM 0516 SM 0904 SM 0908 SM 0912 SM 0916 SM 1708 SM 1712 SM 1716 REF 3274 3275 3276 3277 3278 3279 3280 3281 3282 3283 3284 Number of SAT inputs 4 Sat 1 TV 8 Sat 1 TV 16 Sat 1 TV Number of outp...

Page 5: ...eiver user s receiver receptor usuario receptor usuario SMC 0908 user s receiver user s receiver SMC 0908 user s receiver user s receiver TERR SMU 009 SMU 009 1 1 2 2 3 3 4 6 4 5 7 8 8 MODEL SMC 0908 Ref 3269 MODEL SMC 0908 Ref 3269 SAT A SAT B Features 48 Sat IF polarities plus Terrestrial through SMC cascadable multiswitches MODEL SMC 0904 SMC 0908 SMC 0916 SMC 1708 SMC 1716 REF 3268 3269 3270 3...

Page 6: ...Input Output Sat B vertical low 7 7b Input Output Sat B horizontal low 8 8b Input Output Sat B vertical high 9 9b Input Output Sat B horizontal high 10 Voltage input 11 Grounding Distribución en cascada para 48 usuarios a través de multiswitches SMC Un solo modelo para todos los niveles SMC 0908 user s receiver user s receiver user s receiver user s receiver SMC 0908 SMC 0908 SMC 0908 SMC 0908 SMC...

Page 7: ... Supply General description Features Safety Instructions MODEL SMU 009 Ref 3285 90 240 VAC 50 60 Hz SWITCH MODE POWER SUPPLY MODEL SPS 1820 REF 3287 Mains voltage 90 240 VAC 50 60 Hz Output voltage current 18 VDC 2A ...

Page 8: ...14 15 SMC 0908 SMC 0512 SMU 009 SMU 017 SM 0512 SM 0504 ...

Page 9: ...Ángel Iglesias S A Paseo Miramón 170 20014 San Sebastián Spain Tel 34 943 44 88 00 Fax 34 943 44 88 20 television ikusi com www ikusi tv ...

Reviews: