6.8.2.- PROGRAMMABLE PARAMETERS (TELE-ALIGNED):
PROGRAMMABLE VALUES (TELE-ALIGNED)
Parameter
Default value
Range (programmable values)
PASSWD ID
xxxx
Any combination of 4 functions, excluding 2
nd
speed, STOP and START (Coded)
START (Coded)
Described in the Service Manual
SEARCH MODE
OFF
ON, OFF. (SEARCH MODE)
TOUT LATENCY 4min
1 to 6min; steps of 1 min, and infinite (“INF” value) minutes. (Time to LATENCY state).
TOUT OFF
15min
10 to 20min step of 1 min, and infinite (“INF” value). (Time from LATENCY state to SWITCH OFF state).
TSTOP
2sec
1 to 10sec.: steps of 0,1sec. (Passive STOP time)
OUTMODE MOMENTARY
MOMENTARY
or
LATCHING (OUTPUTS: OPERATING MODES)
SOFTSTART
ON
ON or OFF (Enable or Disable soft start)
SOFTSTOP
ON
ON or OFF (Enable or Disable soft stop)
ACCELRAMP 0,1sec
0,0sec, 0,1sec, 0,2sec, 0,3sec, 0,4sec, 0,5sec, 0,6sec, 0,8sec, 1,0sec, 1,2sec, 1,5sec, 1,7sec, 2.0sec, 2,5sec 3,5sec, 5.0sec (Ramp
acceleration adjustment for each output)
DECELRAMP 0,1sec
0,0sec, 0,1sec, 0,2sec, 0,3sec, 0,4sec, 0,5sec, 0,6sec, 0,8sec, 1,0sec, 1,2sec, 1,5sec, 1,7sec, 2.0sec, 2,5sec 3,5sec, 5.0sec (Ramp
deceleration adjustment for each output)
ASSIGN TABLE
Xxx
Described in the Service Manual
PWM FREQ
300Hz
30Hz to 300Hz ; Step = 10Hz. (R70MP10: PWM output frequency adjustment. Independent for each output).