43
Advanced confi guration of the unit
User interface via web browser
The web interface allows you to fully confi gure the MAC 201 unit through an Ethernet con-
nection and a web browser.
NOTE
To display the graphics provided in the unit confi guration program correctly, we
recommend installing the web browser Mozilla Firefox 1.5 or higher (www.mozilla.
com) in the control PC.
NOTE
Cookies and Javascript must be enabled.
NOTE
Use a PC with an Ethernet network card and an Ethernet CAT-5E crossover cable.
1)
Access the
TCP/IP PROPERTIES
of the PC and confi gure the following parameters:
IP ADDRESS OF THE PC: 192.168.1.1
SUBNET MASK: 255.255.255.0
2)
Connect the PC to the LAN (RJ-45) port of the MAC 201 unit (see number 11 on the
diagram in the section
General description
).
NOTE
The initial process must be made in local mode, although later you will be able to
access the unit from any PC in the LAN.
NOTE
The Ethernet connector of the MAC 201 has two indicator lights:
The link is correct when the link LED (to the left of the Ethernet connector) is
lit.
There is activity in the link when the activity LED (to the right of the Ethernet
connector) is fl ashing.
3)
Launch the web browser and enter the MAC 201 unit's IP address:
INITIAL IP ADDRESS: 192.168.1.6
NOTE
This initial IP address may be modifi ed by the user.
NOTE
The unit also has the IP address 10.254.254.254 assigned by default.