34
Unit installation and confi guration
/ Cascade installation
Cascade installation
The MAC 201 unit has a maximum capacity to include 2 AV analogue TV signals at the RF
VHF/UHF output, coded as COFDM Digital TV signals.
To increase this capacity, several MAC 201 units can be cascade connected. The maximum
capacity of a group of N units is 2xN TV signals included.
To cascade connect 2 or more units, connect the RF output 4 of the previous unit to the
TV input (loopthrough) 3 of the next unit (see
Installation
fi gure).
For installations with 2 or more units, each one must be identifi ed with a different TSID
value and each service identifi ed with a different SID value.
To confi gure TSID and SID values, perform advanced unit confi guration (see
Advanced
confi guration of the unit section).
NOTE
The process of advanced confi guration of the unit is explained in the “Web inter-
face user manual” available at http://www.ikusi.com.
video 3
audio L3
audio R3
AV 4 source
video 4
audio L4
audio R4
AV 3 source
TV +
AV1 +
AV2 +
AV3 +
AV
4
To distribution network
video 1
audio L1
audio R1
AV 2 source
video 2
audio L2
audio R2
AV 1 source
TV (loopthrough)
TV +
AV1 +
AV
2
www.ikusi.com
www.ikusi.com
MAC
201
Ref.4449
MMAC
201
Ref.4449
MAC
201
Ref.4449
MMAC
201
Ref.4449
Manual MAC, TRILINGÜE.indd 34
Manual MAC, TRILINGÜE.indd 34
11/16/2010 1:39:05 PM
11/16/2010 1:39:05 PM