GB-11
GB
| Operating Instructions
Fault
Cause
Remedy
Motor does not run
No voltage
Check connection line and connec-
tion protection switch
Roller blocked
Check roller
Roller does not rotate
Toothed belt defective
Workshop
Motor output drops
Working depth too high
Selected lower working depth
Dirty housing
Clean housing
Lawn too long for scarifying
Lawn too long for scarifying
Poor scarifying perfomance
Working depth too high
Select lower working depth
Worn blades
Replace worn blade
Noisy running, application vibrates
Balde damaged
Workshop
Fault, which cannot be rectified with the help of this table, may only be attended to be an authorized company
(workshop).
12. TROUBLESHOOTING
WARNING!
Only perform the steps described in
these instructions! All further inspection, main-
tenance and repair work must be performed by
a qualified specialist! Contact a specialist if the
problem cannot be solved by yourself!
WARNING!
If the product does not perform prop-
erly, or sound are abnormal, or motor cannot be
started, or stopped as described, or the cutting
device does not work properly, or any other ir-
regularity, or malfunction occurs, do not attempt
to repair the product by yourself.
Please contact helpline or service center.
Before carrying out any maintenance opera-
tions, cut off the electric power supply by dis-
connecting the plug from the extension cable.
Summary of Contents for IEVL 1532