8
-
IKENO INDUSTRIAL DEHUMIDIFIER - USER'S MANUAL - Model ID-series
Subject to change without prior notice
1. Clean the air filter
When cleaning, gently tap the air filter or remove the dust with a vacuum cleaner, or you
can put the air filter in warm water (
≤
40
o
C, add a little neutral detergent ) to wash it or
to brush it, and then wash with clear water.
Attention
a. The air filter should not be exposed directly to sun of fire, to avoid deforming.
b. The air filter should be fixed before starting the dehumidifier.
VI. TROUBLES AND COUNTERMEASURES
Problem
Cause
Solution
Unit does not operate
Power failure
Power source is not
switched on not well
plugged
Fuse is broken
Check and solve problem
Unit does not operate
although there is no power
problem
Room humidity has lower
than set humidity in
humidistat
Turn humidistat to higher
value to see whether the
unit re-operate, the reset
initial position
Capacity reduction
Air filter dusted
Clean air filter
Drained water leaks out
Drain pipe is blocked
Remove the front panel and
wipe off dirt from the pipe
VII. POINTS TO REMEMBER
1. Its outlet dry air temperature is higher than inlet air temperature, but outlet air’s
moisture content is lower. When the dried air is sent to one space, it soon will mix with
the space’s wet air and absorb the humidity. So, normally, space’s humidity will decrease
after half an hour of operation. However, temperature of the space will be little bit higher
if the space uses dehumidifier for drying for a long time.
2. Before being used, the whole set of dehumidifier should be earthed.
3. After opeing the packing, pls. check whether there is any damage of the machine due
to transport, whether the connecting line of each electric parts is tip-off, loosen or cut off.
It there is, please try to repair it.
4. Dehumidifier should be avoided from sunlight and other heat sources, such as burner.
Please let its surrounding air be circulating, especially inlet air entrance.
5. Drain pipe should lead to cloacae lengthened by rubber pipes, so that coagulate water
can be moved out. If no cloaca, then the coagulate water have to be drained outside
6. Turn the knob of humidity controller to required value of relative humidity, then the
compressor can start or stop based on this value, circulating fan will operate continuously.