25. When turn on the machine, if it cannot work, then you should check the connecting 
wires are in a normal situation or not. For circuit drawing, please see the attached picture.  
 
26. If the refrigerating system works normally, please do not open it. For is is the closed 
type, it is no need to add cryogen. 
 
27. When the machine is under operation, if there is metal colliding sound, you should 
stop the machine and check whether the screws of Fan is loosened or disengaged.  
 

28. After 20 minutes’ operation, the drain pipe will have some water to be drained out. 
(Refrigerating water should be full of the basin so that it will be drained out). If the 
temperature/humidity is lower, the time needed will be longer. This is normal.  
 
 

**** 

 
 

If the troubles have not been removed yet, please contact the dealer. 

 
 

 

IMPORTANT USER INFORMATION 

 

Intended use of the unit 

 

The ID-series dehumidifier is inteneded to be used for the dehumidification of air. All other 
uses of the equipment, or use which is contrary to the instructions given in this manual, can 
cause personal injury and/or machine damage.  

 

Warranty and obligations 

 

The warranty period is 12 months from commissioning date unless otherwise advised in 
writing. The warranty is limited to a free exchange complete with free freight, of faulty units 

or components which have failed as a result of faulty quality or defects in manufacture. 

 

Ikeno guarantees that the delivered unit has undergone rigid testing to ensure that the 

specificatoins stated here are fulfilled. All claims on warranty must verify that the fault has 
occurred within the guarantee period., plus that the unit has been used within its operating 
range as stated in the specification. All claims must include the unit type and manufacturing 

number. 

 

Conformity with directives and standards 

 
The Ikeno dehumidifier is designed and manufactured by an EN-ISO 9001 accredited 

development and manufacturing organization. The unit conforms with the specifications in the 

Machinery Directive 98/37/EEC, the Low Voltage Directive 73/23/EEC as amended by 

Directive 93/68/EEC and the EMC Directive 89/336/EEC as amended by Directives 92/31/EEC 

and 93/68/EEC. The standards applied are listed in the EC Declaration of Conformity. 

 

 
 

 

*************************************************************** 

Summary of Contents for ID-3750

Page 1: ...IKENO DEHUMIDIFIER Model ID 3750 Standard type USER S MANUAL...

Page 2: ...1 MAIN FEATURES 2 2 COMPONENT IDENTIFICATION 3 3 WORKING PRINCIPLE 3 4 DIMENSION 4 5 SPECIFICATION 5 6 MOISTURE REMOVAL CAPACITY 5 7 ELECTRICAL DIAGRAM 6 III INSTALLATION 1 RECEIVING INSPECTION 7 2 WO...

Page 3: ...n Model ID series designed by our company is the most reliable unit in the range It dehumidifies air by dropping air temperature below its dew point to condensate out moisture vapor The condensation w...

Page 4: ...cumulator magnetic flow control valve evaporator coil condenser coil capillary tube centrifugal fan temperature sensor humidity sensor and electrical wiring The centrifugal fan makes wet air entering...

Page 5: ...er defrosting the dehumidifier will turn back to run normally In order to protect the unit from severe damage during operation the unit is equipped with such a safety features such as low pressure cut...

Page 6: ...ithout prior notice 5 SPECIFICATION STANDARD MODEL Type ID 3750 Capacity L h 13 Flow m3 h 3000 Power Kw 5 5 Note Nominal working condition 27 0o C DB 21 2o C WB Low temperature working condition 5 0o...

Page 7: ...R USER S MANUAL Model ID series Subject to change without prior notice 7 ELECTRICAL DIAGRAM COMP Compressor TR1 Time relay 3 min TR2 Time relay 30 min LTP Low pressure switch HTP High pressure switch...

Page 8: ...re Provide automatic circuit breaker There should be reliable electrical grounding 4 Other requirement Skilled professional personnel should perform maintenance of the unit Parking inclination of the...

Page 9: ...the pipe VII POINTS TO REMEMBER 1 Its outlet dry air temperature is higher than inlet air temperature but outlet air s moisture content is lower When the dried air is sent to one space it soon will m...

Page 10: ...ct The running direction of fan wheel points to machine s fron face 14 Adjust humidity controller set one required humidity value 15 Press ON button to start Fan 16 The compressor will start after 3 m...

Page 11: ...or use which is contrary to the instructions given in this manual can cause personal injury and or machine damage Warranty and obligations The warranty period is 12 months from commissioning date unle...

Page 12: ...Assembled in Thailand...

Reviews: