Ikelite controls are designed to provide years of reliable service

with minimal maintenance.

1. Push button controls require no maintenance other than rinsing

in fresh water after saltwater use. If a push button control

becomes difficult to push or if it sticks when depressed, soak the

housing in luke warm fresh water. After a few minutes, operate

the push button. If this does not correct the problem, return the

housing to Ikelite for maintenance.

2. Some of the controls have long shafts. These controls can be

pulled out, exposing the shaft (see Diagram B on page #24). 

To lubricate the control, gently pull on the knob until the

stainless steel shaft is exposed. Lightly lubricate the shaft, then

move the shaft in and out several times. This will lubricate the

x-ring in the Ikelite control gland. This should be done before

using the housing after a prolonged storage period, or once a

week when the housing is in constant use.

3. Some of the controls have a short shaft and cannot be pulled

out exposing the shaft for lubrication. In the unlikely event one

of these controls sticks or becomes difficult to operate you can

remove the control from the housing and lubricate it, or return

the housing to Ikelite for maintenance. To remove the control

(see Diagram A on Page #24), loosen the set screw in the knob

(allen wrench required); remove the knob. If there is salt or dirt

build-up on the exposed control shaft, clean the shaft. Open the

housing and gently slide the control shaft out of the control

gland. Clean and lightly lubricate the shaft, including the end of

the shaft. 

24

CCoonnttrrooll M

Maaiinntteennaannccee CCoonntt..

4. Slide the shaft back into the control gland and gently slide it

back and forth a few times without fully removing the shaft

from the gland. Replace the knob noting the flat area on the

shaft. The set screw in the knob should tighten down against

the flat area on the control, so the knob does not turn on the

shaft.

housing

lubricate shaft

pull out to
expose shaft

Diagram B

Loosen set screw

Tighten set screw down

against this flat area

when replacing the knob.

housing

gland

control

Lubricate end of shaft
before reinserting into
gland

Diagram A

PPrree--D

Diivvee YYoouurr SSyysstteem

m

It is recommended that you take the complete system into a

swimming pool before use in open water. This will give you a

chance to become familiar with the handling and operation of

your housing and strobe(s).

O

Oppttiioonnaall AAcccceessssoorriieess

LLeeaadd W

Weeiigghhtt #

#00990066..5588

The buoyancy of the system will depend on the size and

number of strobes used as well as the weight of the camera.

Ideally the system should be slightly negative in the

environment in which it will be used. If you need to add weight

to the system, an optional lead weight is available. To add the

lead weight remove the (2) screws from the bottom of the

aluminum tray. Place the lead weight into the pocket of the

aluminum tray and reattach.

While both the Port and Back o’rings should last quite some time, it

is best to carry a spare, in case one becomes damaged or lost.

#

#55551122..6699 O

O--rriinngg KKiitt ((RReeccoom

mm

meennddeedd))

#

#55551122..6699 O

O--rriinngg KKiitt iinncclluuddeess:: 

IIkkeelliittee LLuubbee #

#00118844..11

PPoorrtt O

O’’rriinngg #

#00110055

H

Hoouussiinngg BBaacckk O

O’’rriinngg #

#00113322..6611

SSttoorriinngg tthhee H

Hoouussiinngg

When the housing is going to be stored for a prolonged period it

should be soaked in a mild soap solution, rinsed and dried

thoroughly. Remove the back and port from the housing.

Remove the back and port o’rings, lightly lubricate them and

place them in a plastic zip-lock bag. Place the plastic bag inside

the housing for storage. Operate the push buttons periodically.

22

21

LLuubbrriiccaannttss

1. Ikelite provides silicone lubricant with the housing. We

recommend that you use only Ikelite lubricant. Other brands

may cause the o’ring to swell and not seal properly.

2. Use only enough Ikelite lubricant to lightly cover control shafts

and o’rings. Wipe off any excess lubricant with a clean cloth.

Lubricant is not a sealant and is used to reduce friction.

Excessive lubricant can collect sand and dirt which may

interfere with proper sealing.

N

Noottee:: Lubricant is not needed on the main housing o’ring to

maintain a housing seal, however, lightly lubricating this o’ring

can extend it’s life and aid in seeing a good housing seal. Too

much lube can attract debris increasing the potential for a leak.

CCAAU

UTTIIO

ON

N::

N

Neevveerr uussee sspprraayy lluubbrriiccaannttss aass tthhee pprrooppeellllaanntt iinnggrreeddiieenntt

c

caann ccaauussee tthhee ppllaassttiicc hhoouussiinngg ttoo ccrraacckk..

Summary of Contents for SLR-DC 6812.31

Page 1: ... S N Multi Selector Right O Multi Selector Down P Flash Exposure Control Dial Q Live View Button R AF Area Mode Selector S Info Button WB ISO QUAL Mode E TTL 1 1 1 F 2 3 MAN FRONT VIEW BACK VIEW 3 SIDE VIEW Camera Tray Camera Mounting Bolt Gear Sleeve Port O ring Port Lock Optional Port Lid Snap Back O ring AE L AF L Power Switch Mode Shutter Release O Op pe en ni in ng g t th he e H Ho ou us si i...

Page 2: ...th 0073 sleeve 0073 sleeve Use with small diameter zoom clamp 9059 8 Figure A Normally used with Type 2 lens Fig 2 5509 28 Package 9059 9 large diameter clamp For use with 0073 1 sleeve 0073 1 sleeve Use with large diameter zoom clamp 9059 9 Figure B thick ribs thin ribs wide grooved extension tabs narrow grooved extension tabs Figure F 7 8 I In ns st ta al ll li in ng g t th he e C Ca am me er ra...

Page 3: ...stalling the thinnest rubber strips If the Zoom Clamp still is not tight enough and meshes improperly with the Gear Sleeve use the thicker rubber strips Reinstall the Zoom Clamp Sleeve and Port Mesh Gear Sleeve teeth with Black Housing Drive Gear Fig G Page 1 2 10 N NO OT TE E Before installing the lens port and checking operation make sure the teeth on the Gear Sleeve mesh with the teeth on the h...

Page 4: ...his housing has Conversion Circuitry built into the housing When used with Ikelite DS Substrobes the Conversion Circuitry provides real Nikon iTTL flash exposure with over and under exposure compensation from 11 3to 11 3f stops in 1 3 stop increments N NO OT TE ES S F Fl la as sh h E Ex xp po os su ur re e C Co om mp pe en ns sa at ti io on n s se et t i in n t th he e c ca am me er ra a w wi il l...

Page 5: ...ion of particles in the water and helps to eliminate backscatter 17 Substrobe DS51 Actual Size 8 cm dia x 12 cm 3 2 dia x 4 7 D DS S1 16 61 1M Mo ov vi ie e S Su ub bs st tr ro ob be e The DS1 61Movie Substrobe combines all of the functionality of our renowned DS1 60 with a powerful 500 lumen LED video light Three super bright LEDs are arranged behind a special optical element to provide 45 degree...

Page 6: ...fore use in open water This will give you a chance to become familiar with the handling and operation of your housing and strobe s O Op pt ti io on na al l A Ac cc ce es ss so or ri ie es s L Le ea ad d W We ei ig gh ht t 0 09 90 06 6 5 58 8 The buoyancy of the system will depend on the size and number of strobes used as well as the weight of the camera Ideally the system should be slightly negati...

Page 7: ... part 031 9 1 2 C CA AU UT TI IO ON N N Ne ev ve er r u us se e s sp pr ra ay y l lu ub br ri ic ca an nt ts s a as s t th he e p pr ro op pe el ll la an nt t i in ng gr re ed di ie en nt t c ca an n c ca au us se e t th he e p pl la as st ti ic c h ho ou us si in ng g t to o c cr ra ac ck k G Ge en ne er ra al l T Ti ip ps s 1 You should completely assemble and test your system in a swimming pool...

Reviews: