![Ikegami MKC-300HD Operation Manual Download Page 16](http://html1.mh-extra.com/html/ikegami/mkc-300hd/mkc-300hd_operation-manual_2041762016.webp)
12
■
Electrical Connection
Turn on power supply to the monitor and other external equipment. Check that
CCU and the camera head are connected with a camera cable, and then turn on
power supply (POWER switch) of CCU.
When power to CCU is turned on, MKC-300HD (CAMERA HEAD+CCU) is
initialized by the built-in computer. The pictures on the monitor are not stable
during this period. However it is not a failure.
When initialization is finished, the video image from the camera is output under
the same setting condition with the last use. (Note1)
* When moving the CCU, be sure to turn off the POWER switch, disconnect the
power plug and remove the connecting cable between equipment beforehand.
CAUTION
Caution for Camera cable connection and disconnection
Turn off the power of MKC-300HD when you connect or
disconnect the camera cable. If the CCU is turned on, it may
cause the fault of MKC-300HD.
NOTE: Phenomenon on video image
MKC-300HD may happen following phenomenon on its video
image. It is not failure but it is because of employing CMOS
sensor
When its sensitivity gain is going up and/or when it is slow
shutter mode, it may appear high lighting dots. In case under
high temperature condition, it may be remarkable.
It may appear horizontal stripe pattern or flicker on a video
image under the fluorescent lighting. In this case, please use
manual electrical shutter of 1/100 (50Hz area) or 1/120 (60Hz
area). It will be reduce, but please note that it will not
disappear at all.
In case of fast moving object on a video image, it may appear
distortions.
Note1
When power is turned off in the state of still screen picture, that state will not be held
even if power is turned on again, and MKC-300HD is set to the normal shooting state.
DN-