4. Advanced Usage Methods
4.1. External synchronization
If this equipment is used with external synchronization, SYNC is input to the GENLOCK terminal on the back
of the CCU. If SYNC is input to the GENLOCK terminal, the camera automatically switches from internal
synchronization to external synchronization.
SYNC input condition: 3-value SYNC: 0.6 Vp-p/75 Ohms
4.1.1. Wiring connection example
Prepare two sets of CCU and camera for the MKC-210HD. Connect the SYNC connector of CCU (Master) and
the GENLOCK connector of CCU (Slave) with the coaxial cable.
RS-232C
VBS
Y/C
DVI
FOOT SW
SYNC
POWER
GENLOCK
1
2
HD SDI
IRIS
CAMERA
RS-232C
VBS
Y/C
DVI
FOOT SW
SYNC
POWER
GENLOCK
1
2
HD SDI
IRIS
CAMERA
MKC-210HD
Camera
(Master)
CCU (Master)
MKC-210HD
Camera
(Slave)
Coaxial cable
(Sold separately)
CCU (Slave)
SYNC
SYNC Connector
Connector
SYNC Connector
GENLOCK Connector