E-5
5. Applied connections
Connecting to the alarm terminals
5-1. Connecting to the alarm terminals
Make sure in advance that the camera power is not turned on.
* Typical connections
Max DC24V 50mA
No-voltage contact
External unit’s alarm input
Alarm
+24V
10K
Ω
Open collector
* Alarm action
IN
: If an alarm signal comes in, the alarm message is e-mailed to a designated ad-
dress. An alarm output is given.
OUT : If the alarm input is short-circuited or the motion detector is activated, an output is
given for a specified time.
5-2. Connecting to the MIC and AUDIO terminals
Make sure in advance that the camera power is not turned on.
* Typical connections
AMP
Microphone
Speaker
* Audio connections
The camera’s audio signal is sent to the client PC. The voice via the client PC’s micro-
phone is outputted.