![IKEA GRUNDLAGGA 304.620.42 Manual Download Page 7](http://html1.mh-extra.com/html/ikea/grundlagga-304-620-42/grundlagga-304-620-42_manual_2041420007.webp)
7
Installation with
cabinets
Check location where the range
will be installed for proper
electric and gas supply, and
stability of the floor.
The dimensions shown here
must be used and are minimal
unless otherwise stated. These
measurements do not allow
for any clearance below the
cooking top or at the rear of
the range.
Contact surface must be solid
and level.
Things to remember:
• Do not seal the range to
side cabinets.
• Do not pinch the power
supply cord between the
range and rear wall.
• If cabinet depth is greater
than 25”, the oven front
frame must extend beyond
cabinet front by 1/2”
minimum (See Fig. 1).
• All openings in the wall or
floor where the range is to
be installed must be sealed.
2”
7”
Recommended
area for 120V
outlet on rear
of wall and area
for thru the wall
connection of
pipe stub and
shut-off valve.
18”
Min. to cabinets on
either side of range
30”
30”
Min. height from
cooktop to cabinets
25”
24”
*15”
23”
36”
Std.
30”
11-1/2”
Installation beside wall
If installing beside a wall, the minimum distance to
combustible wall on either side of range above 35¾”
height should be according to the BTU of the largest
burner (See Fig 2).
36±1/8”
(Adjustable)
46-
5/8”
max
door
open
29-7/8”
**see
above
48-1/2”
max
30”
29-1/4”
max
door
closed
Fig. 1
Fig. 3
Fig. 2
10-1/2”
15”
Max.
Recommended area for
thru the floor connection
of gas pipe stub and shut-
off valve.
* 9500 BTU or less
2”
10,000 - 16,999 BTU 3”
17,000 BTU or greater 5”
*
* Models without self-clean
feature may have an additional
7 inches clearance from the
floor.
35¾” Min.
(90.8 cm)
**28-3/4" with door handle
26-3/8" without door handle
Summary of Contents for GRUNDLAGGA 304.620.42
Page 1: ...LAGAN MOTSVARIG GRUNDLÄGGA ES FR EN ...
Page 5: ...5 ...
Page 19: ...19 ...
Page 33: ...33 ...
Page 44: ...44 AA 2195041 2 A17725904 Inter IKEA System B V 2020 2020 02 01 23430 ...