Periodic Fixture Inspection
1. The condition of the internal wiring and ceramic base will need to be inspected and tested every 4000 working hours or at least once a year. This
frequency may need to be increased if the fixture has endured rough treatment. All internal components should only be replaced with Lightstar
spare parts.
2. The lamps should be checked every 100 working hours. The lamp should be changed if the lamp becomes deformed or damaged, otherwise
explosion might occur. Defer to instructions provided by the lamp manufacturer.
3. Always check the safety shield before every use.
4. All high-voltage components (ex: voltage wires, lamp ceramic, external shield, igniter must be inspected every 100 working hours or at least once a
year.
5. Outer door hinges and latching system must be checked every 250 working hours to ensure proper seating of the safety shield. This will allow
inspections of accessories and the holding clamps.
6. The condition of the internal mirror must be maintained every 250 working hours. It must be replaced whenever it becomes either cracked or
broken. It is essential for the performance of the fixture.
Specifications & Photometrics
LSC-003 Specifications
Beam Angle
6° to 58°
Build Material
Aluminum
Color Temperature
5600K
Cooling System
Air Cooled
Fixture Size
23.3 x 16.3 x 12.8 in.
Fixture Weight
24 lbs
Focusing
Knob Control
Head Type
HMI Fresnel 1200W
IP Class
IP23
Lamp Base
1200W / 100V / G38
Lens Size
Fresnel 6.9"
Yoke
Cast Aluminum with 1 1/8" Pin
LUX
METERS
3M
4M
6M
7M
8M
5M
46880
20800
11700
LUX
METERS
3M
4M
6M
7M
8M
5M
3125
1390
780
FC
FEET
13'
19'
26'
4355.3
1032.3
1086.9
FC
FEET
13'
19'
26'
292.8
129.1
72.4