Safety instructions

/// General information

› 

Read the operating instructions completely before starting up and follow the safety 

instructions.

›  Keep the operating instructions in a place where it can be accessed by everyone�
›  Ensure that only trained staff work with the device�
›  Follow the safety instructions, guidelines, occupational health and safety and accident 

prevention regulations�

 

Danger!  

›  Pay attention to the marked sites in Fig� 1� 
  Beware of the risk of:
  - flammable materials
  - glass breakage as a result of mechanical stirring power

 Caution!   

›  Wear your personal protective equipment in accordance with the hazard category of the 

medium to be processed, there is a risk of:
- splashing of liquids

  - projectile parts

- body parts, hair, clothing and jewellery getting caught�

›  The device must only be used in a technically perfect condition�

/// Device setup

  Danger!  

›  Users must make sure that the standby key of the IKA device can be accessed immediately, 

directly and without risk at any time� If installation or positioning cannot ensure this access 
at all times, an additional 

EMERGENCY STOP

 switch that can be easily accessed must be 

installed in the work area�

 

Warning!    

›  Ensure stable assembly� The vessel used for stirring must be secured�
›  Use stirring shaft protective equipment!

!

 Notice!

›  Set up the stand in a spacious area on an even, stable, clean, non-slip, dry and fireproof surface�
›  Remove the chuck key from the chuck before turning on the device�
›  Place the power supply outside the working area of the device� 
›  Avoid knocking and impacting on the lower end of the shaft and the chuck gear teeth� Even 

minor, invisible damage can lead to imbalance and uneven shaft action�

›  You must ensure that the stirring element is securely clamped in the chuck!
›  All screw connections must be properly tightened�
›  The high torque developed by the device requires particular care in the choice of stand, cross 

sleeve and anti-rotation element for the agitating vessel�

!

EU Declaration of conformity

We declare under our sole responsibility that this product corresponds to the directives 2014/35/
EU and 2006/42/EC

2014/30/EU and 2011/65/EU and conforms with the following standards or 

normative documents: EN 61010-1, EN 61010-2-051, EN 61326-1, EN 60529 and EN ISO 12100�
A copy of the complete EU Declaration of conformity can be requested at sales@ika�com�

Source language: German

Explication of warning symbols

/// Warning symbols

Indicates an (extremely) hazardous situation, which, if not avoided, will 
result in death, serious injury�

Danger:

Indicates a hazardous situation, which, if not avoided, can result in 
death, serious injury�

Warning:

Indicates a potentially hazardous situation, which, if not avoided, can 
result in injury�

Caution:

!

Indicates practices which, if not avoided, can result in equipment damage�

Notice:

/// General Symbols

Position number

A–––

Correct/Result
Shows the correct execution or the result of an action step�

Wrong
Shows the incorrect execution of an action step� 

Note
Displays action steps that require particular attention to detail� 

Beep
Shows action steps where audible beeps can be heard�

Summary of Contents for NANOSTAR 7.5 digital

Page 1: ...IKA NANOSTAR 7 5 digital...

Page 2: ...3 ENGLISH...

Page 3: ...of warning symbols 6 Safety instructions 7 Intended use 9 Unpacking 10 Technical data 23 Operation 18 Speed 11 Output shaft 11 Operator panel and display 12 USB interface 19 Maintenance and cleaning 2...

Page 4: ...e Place the power supply outside the working area of the device Avoid knocking and impacting on the lower end of the shaft and the chuck gear teeth Even minor invisible damage can lead to imbalance an...

Page 5: ...spraying of the medium to be stirred Ensure that the stand does not start to move Only process media that will not react dangerously to the extra energy produced through processing This also applies...

Page 6: ...rmal operations the speed value on the display corresponds to the speed of the output shaft in revolutions per minute rpm Output shaft The clamping chuck and output shaft permit clamping IKA recommend...

Page 7: ...sconnection from the power supply network B Display Display the speed value C Control knob Rotating Pressing Set the speed by rotating Start stop the stirrer function by pressing Installation Assembli...

Page 8: ...14 15 2 x 1 2 rpm Assembling the stirring element using the chuck Assembling the stirring shaft protector rpm 2 3 1 Securing the mixing vessel to the stand 2 1 2 2 1 1 2 1 1 2 3...

Page 9: ...eable adapter Notice The AC adapter is suitable for 100 VAC to 240 VAC The exchangeable adapter for the relevant country must be attached before the AC adapter is plugged into the mains socket Click C...

Page 10: ...ne is ready for operation when the mains plug is plugged in If these conditions are not met safe operation is not guaranteed and the machine could be damaged Observe the ambient conditions temperature...

Page 11: ...nents and their statistical failure rate Cleaning For cleaning disconnect the mains plug Use only cleaning agents which have been approved by IKA to clean the device water containing surfactant isopro...

Page 12: ...oper use insufficient care or maintenance not carried out in accordance with the instructions in this operating manual Technical data Drive unit Speed range under nominal load rpm 0 50 2000 Speed adju...

Page 13: ...England LTD Phone 44 1865 986 162 eMail sales england ika com MALAYSIA IKA Works Asia Sdn Bhd Phone 60 3 6099 5666 eMail sales lab ika my CHINA IKA Works Guangzhou Phone 86 20 8222 6771 eMail info ik...